Welcome to our new website, found an issue or bug? Please report it here

TJ36-SB-chb
Thermocouple Probes with SS Overbraid Cable & Mini Connector
- Stainless Steel Overbraid Resists Abrasions and Cuts, yet Remains Flexible
- 1 m (40 in.) Lead Length
- 304 SS and Inconel® 600 sheaths. Additional Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
- Manufactured with OMEGACLAD™ Compacted Mineral Insulation Cable for Long-Lasting, Low-Drift Performance in Harsh Conditions!

Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
For long life, drift-free operation, choose Super OMEGACLAD™ XL mineral insulated thermocouple cable and our rugged transition joint probes, which are available in Type K and N calibrations. PFA lead wire with a stainless steel overbraid resists abrasions and provides a cost-effective solution for environmental temperatures to 260°C (500°F). See the highlighted section in the table.
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.
View the Thermocouple Accuracy and Color Code charts
Calibration ANSI Code | Sheath Materials | Sheath Dia. mm (in.) | T/C Junction Upper Temp. °C (°F) | Model Number (See notes, below) |
K Chromega® - AL | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 899 (1650) 899 (1650) 899 (1650) 899 (1650) | TJ36-CASS-116(*)-(**)-SB-SMPW-M TJ36-CASS-18(*)-(**)-SB-SMPW-M TJ36-CASS-316(*)-(**)-SB-SMPW-M TJ36-CASS-14(*)-(**)-SB-SMPW-M |
INC600 | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 921 (1690) 1071 (1960) 1149 (2100) 1149 (2100) | TJ36-CAIN-116(*)-(**)-SB-SMPW-M TJ36-CAIN-18(*)-(**)-SB-SMPW-M TJ36-CAIN-316(*)-(**)-SB-SMPW-M TJ36-CAIN-14(*)-(**)-SB-SMPW-M | |
Super OMEGACLAD™ XL | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 1038 (1900) 1149 (2100) 1204 (2200) 1204 (2200) | TJ36-CAXL-116(*)-(**)-SB-SMPW-M TJ36-CAXL-18(*)-(**)-SB-SMPW-M TJ36-CAXL-316(*)-(**)-SB-SMPW-M TJ36-CAXL-14(*)-(**)-SB-SMPW-M | |
J Iron- Constantan | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 441 (825) 521 (970) 621 (1150) 721 (1330) | TJ36-ICSS-116(*)-(**)-SB-SMPW-M TJ36-ICSS-18(*)-(**)-SB-SMPW-M TJ36-ICSS-316(*)-(**)-SB-SMPW-M TJ36-ICSS-14(*)-(**)-SB-SMPW-M |
T Copper- Constantan | 304SS | 1.59 (1/16) 3.18 (1/8) 4.78 (3/16) 6.35 (1/4) | 260 (500) 316 (600) 371 (700) 371 (700) | TJ36-CPSS-116(*)-(**)-SB-SMPW-M TJ36-CPSS-18(*)-(**)-SB-SMPW-M TJ36-CPSS-316(*)-(**)-SB-SMPW-M TJ36-CPSS-14(*)-(**)-SB-SMPW-M |
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.), or 18 for 450 mm (18 in.).
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute NN for CA in Model Number. See ordering examples below.
View the Thermocouple Accuracy and Color Code charts