1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback
DP20-Series
Panel Meter - 1/8 in DIN, Temperature, Process
Models In Stock
- Fast Access Menu—Front Key Access to Modify the Alarm Setpoints and Max/Min Memory
- External Control Function—Contact at Multifunctional Terminal 5 (Second Scaling, Decimal Point Change, ‘Hold’ the Reading or Activate the Max/Min Memory)
- Automatic, Power Saving Eco Mode
- Alarms 1 or 2, Independent, Configurable as Max/Min, with Setpoint and Hysteresis
DP20-Series
From
$
155.44
Models In Stock

Product Overview
- Analog Input Note 4 to 20 mA, 0 to 10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
- Applications Assembly Line, Control Panel, Laboratories and Scientific
- Decimal Points Configurable
- Digit Size 14 mm
- Display Range -1999 to 9999
- Display Type 3.5 Digit LED
- Electrical Connection Screw Terminal
- Enclosure Ratings IP65, NEMA Type 4
- Form factor 1/8 DIN
- Input Type Thermocouple, RTD, Thermistor, Current, Voltage, DC or AC, Resistance, Frequency
- Measuring Range Thermocouple: Type K: -100 to 1350 °C;Type J: -100 to 1200 °C;Type E: -100 to 1000 °C;Type N: -100 to 1300 °C;Type L: -100 to 900 °C;Type R: 0 to 1768 °C;Type S: 0 to 1768 °C;Type T: -100 to 400 °C;Type C: 0 to 2300 °C;Type B: 700 to 1820 °C ;RTD: Pt100(3 wires): 200 to 700 °C ;Pt100(2 wires): 200 to 700 °C ;Pt500: -150 to 630 °C ;Pt1000: -190 to 630 °C ;Ni100: -60 to 180 °C ;Ni200: -60 to 120 °C ;Ni1000: -60 to 180 °C ;Resistance: 0 to 5K: from 9999 to -1999;0 to 50K: from 9999 to -1999;Potentiometers Nominal Value: 500 R to 20 K: from 9999 to -1999;Frequency: 15 Hz to 100 Hz: from 9999 to -1999; Signal Ranges: AC Voltages and AC Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure) ;DC Voltages and DC Currents: ± 600 Vdc, ± 200 Vdc, ± 20 Vdc, ± 2 Vdc, ± 200 mVdc, ± 60 mVdc, ± 5 Adc, ± 20 mAdc;Refer Tables for more information; Analog Input: 4 to 20 mA, 0 to 10 Vdc
- Number of Inputs 1
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Power Consumption 2.5 W
- Probe Type Resistive ‘Pt’ Probes: Pt100 with 2 and 3 wires, Pt500, Pt1000 Resistive ‘Ni’ Probes: Ni100, Ni200, Ni1000 Resistive NTC Probes: See table at page 4 Resistive PTC Probes: Families KTY-121, KTY-210 and KTY-220
- Reading Rate 3/sec
- Resistance Measurement Range Up to 20 KΩ
- Response Time <300 ms. (0 % to 99 % of signal)
- Sampling Rate 3 Hz (3 updates/second)
- Sensor/Transmitter Power 15 Vdc
- Span Temperature Drift 150 ppm/°C
- Supply Power Note 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
- Supply Power Type AC/DC
- Supply Voltage 18 to 264 Vac/Vdc
- Thermal Effects 150 ppm/°C
- Thermocouple Type J, K, T, E, R, S, B, C, N, L
- Weight 150 g
OMEGAs DP20 series new universal panel meter delivers high performance in a 1/8 DIN size for panel mount, and integration in a wide range of applications. The DP20 accepts universal inputs, including thermocouple, RTD, process (mA & Vdc), resistance, and true RMS voltage and current. By configuration, it will work as an AC and DC voltmeter (up to 600 V) and AC and DC ammeter (up to 5 A) offering application flexibility for process control and industrial requirements. A single universal power supply allows this unit to be suited for global use.
Introduce Omega DP20 Series The optional relays, analog output, and Modbus® RTU serial communications provide customization, control and communication capability. Additional features of the economical DP20 panel meter include scaling, NEMA 4 (IP65) protection, and programmable decimal points.
Specifications
Digits: 4
Reading: 9999 / -1999
Decimal Point: Configurable
LED Color: Red
Digit Height: 14 mm (0.55")
Accepted Signal Ranges: See tables on pdf page 4 for more information
AC Voltages and AC Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents: ±600 Vdc, ±200 Vdc, ±20 Vdc, ±2 Vdc, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Thermocouples: K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Probes:
Resistive † ˜Pt Probes: Pt100 with 2 and 3 wires, Pt500, Pt1000
Resistive † ˜Ni Probes: Ni100, Ni200, Ni1000
Resistive NTC Probes: See table at page 4
Resistive PTC Probes: Families KTY-121, KTY-210 and KTY-220
Process: 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Resistances: Ranges 0/5 K and 0/50 K
Potentiometers: With nominal values from 500 R up to 20 K
Thermal Drift Offset+Span: 150 ppm/ ºC
How to Open/Close the Omega DP20 Housing Readings: 3 readings/ second
Refresh: 3 readings/ second
Response Time: <300 mSec. (0 % to 99 % of signal)
Power † ˜U: 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Output and Control Options:
1 or 2 Relays: 1 Analog output 4/20 mA isolated
1 Modbus RTU isolated serial output
Protection: NEMA 4 (IP65)
Consumption (Normal Mode): <1.0 W (meter only) <2.5 W (meter with options)
Consumption († ˜Eco Mode): <0.3 W (meter only) <1.5 W (meter with options)
Connections: Plug-in screw terminals
Weight: <150 g (5.3 oz)
Operation Temperature: 0 to 50 ºC (32 to 122 ºF)
Read More
Specifications
Digits: 4
Reading: 9999 / -1999
Decimal Point: Configurable
LED Color: Red
Digit Height: 14 mm (0.55")
Accepted Signal Ranges: See tables on pdf page 4 for more information
AC Voltages and AC Currents: 600 Vac, 200 Vac, 20 Vac, 2 Vac, 200 mVac, 60 mVac, 5 Aac, 20 mAac (True RMS measure) (accepts phase-neutral and phase-phase measure)
DC Voltages and DC Currents: ±600 Vdc, ±200 Vdc, ±20 Vdc, ±2 Vdc, ±200 mVdc, ±60 mVdc, ±5 Adc, ±20 mAdc
Thermocouples: K, J, E, N, L, R, S, B, T and C (automatic cold junction compensation)
Probes:
Resistive † ˜Pt Probes: Pt100 with 2 and 3 wires, Pt500, Pt1000
Resistive † ˜Ni Probes: Ni100, Ni200, Ni1000
Resistive NTC Probes: See table at page 4
Resistive PTC Probes: Families KTY-121, KTY-210 and KTY-220
Process: 4/20 mA, 0/10 Vdc (+15 Vdc excitation voltage configurable at terminal 5)
Resistances: Ranges 0/5 K and 0/50 K
Potentiometers: With nominal values from 500 R up to 20 K
Thermal Drift Offset+Span: 150 ppm/ ºC
Refresh: 3 readings/ second
Response Time: <300 mSec. (0 % to 99 % of signal)
Power † ˜U: 18 to 265 Vac/dc (isolated 1500 Veff @ 60 seconds)
Output and Control Options:
1 or 2 Relays: 1 Analog output 4/20 mA isolated
1 Modbus RTU isolated serial output
Protection: NEMA 4 (IP65)
Consumption (Normal Mode): <1.0 W (meter only) <2.5 W (meter with options)
Consumption († ˜Eco Mode): <0.3 W (meter only) <1.5 W (meter with options)
Connections: Plug-in screw terminals
Weight: <150 g (5.3 oz)
Operation Temperature: 0 to 50 ºC (32 to 122 ºF)
PDFs & Manuals