Welcome to our new website, found an issue or bug? Please report it here

OM-EL-USB-1-Series
Portable Data loggers with USB Interface
Models In Stock
- Temperature, Temperature/RH/Dew Point, Voltage and Current Models
- Datalogger Plugs Directly into Computer ’s USB Port for Easy Setup and Data Download (No USB Cable Required)
- User-Programmable Alarm Thresholds with LED Indicators
- Bright Red,Green and Orange LED Indication
OM-EL-USB-1-Series
From
$
128.91
Models In Stock

Product Overview
- Battery Size and Type 1/2 AA Li-ion
- Data Interface USB
- Enclosure Ratings IP67
- Form factor Handheld
- Supply Power Type Battery
The OM-EL-USB Series of data loggers includes models for temperature, temperature/relative humidity, voltage, and current measurement. The user can easily set up the data logger and download the stored data by plugging the module into a PC"s USB port and running the easy-to-use Windows software. Software-selectable setup parameters include logging rate, start-time, high/low alarm settings, and temperature units (°C or °F). Data can then be graphed, printed, and exported to other applications such as Excel. Each data logger is supplied complete with a long-life lithium battery. Built-in LED indicators show data logger status. OM-EL-USB Series data loggers are protected against moisture to IP67 standards when the protective cap is fitted.
Specifications
Specifications
OM-EL-USB-1 TEMPERATURE DATA LOGGER Range: -35 to 80°C (-31 to 176°F) Resolution: 0.5°C (1°F) Accuracy: ± 1.0°C (± 2.0°F) GENERAL Memory: 16,000 temperature readings Logging Interval: 10 sec. to 12 h. Operating Temperature Range: -35 to 80°C (-31 to 176°F) Alarm Thresholds: High/low alarm thresholds selectable in software Start Date/Time: Selectable in software Status Indicators (LEDs): Red, green and orange Software: Windows 2000/XP/Vista/7 (32- and 64-bit) Power: ½ AA 3.6 V lithium battery (included) Battery Life: 1 year (at 25°C and 1 minute logging interval) Weight: 43 g (1.5 oz) Dimensions: See dimensional drawing ![]() | ![]() |
OM-EL-USB-2 AND OM-EL-USB-2-PLUS TEMPERATURE AND RELATIVE HUMIDITY DATA LOGGER (DEW POINT INDICATION VIA WINDOWS SOFTWARE) TEMPERATURE Range: -35 to 80°C (-31 to 176°F) Resolution: 0.5°C(1°F) Accuracy: OM-EL-USB-2: ± 0.5°C (± 1.0°F); OM-EL-USB-2-PLUS: ± 0.3°C (± 0.6°F) HUMIDITY Range: 0 to 100% RH Resolution: 0.5% RH Accuracy 20 to 80% RH; OM-EL-USB-2: ± 3.5% RH OM-EL-USB-2-PLUS: ± 2.0% RH DEW POINT Accuracy (overall error in the calculated dew point for RH measurements from 40 to 100% RH @ 25°C): ± 2°C (± 4°F) GENERAL Memory: 16,000 temperature and 16,000 relative humidity readings Logging Interval: 10 seconds to 12 hours Operating Temperature Range: -35 to 80°C (-31 to 176°F) Alarm Thresholds: High/low alarm thresholds for % RH and temperature, selectable in software Start Date/Time: Selectable in software Status Indicators (LEDs): Red and green Software: Windows 2000/XP/Vista/7 (32- and 64-bit) Power: ½ AA 3.6 V lithium battery (included) Battery Life: 1 year typical (depends on sample rate, ambient temperaure and use of alarm LEDs) Weight: 57 g (2 oz) Dimensions: See dimensional drawing | ![]() |
OM-EL-USB-3 VOLTAGE DATA LOGGER Range: 0 to 30 Vdc Resolution: 100 mV Accuracy: ± 1% GENERAL Memory: 32,000 voltage readings Logging Interval: 1 seconds to 12 hours Operating Temperature Range: -25 to 80°C (-13 to 176°F) Alarm Thresholds: High/low alarm thresholds selectable in software Start Date/Time: Selectable in software Status Indicators (LEDs): Red and green Power: ½ AA 3.6 V lithium battery (included) Battery Life: 1 year typical (depends on sample rate, ambient temperature and use of alarm LEDs) Weight: 57 g (2 oz) Dimensions: See dimensional drawing | ![]() |
OM-EL-USB-4 CURRENT DATA LOGGER Range: 4 to 20 mA Resolution: 0.1 mA Accuracy: ± 1% GENERAL Memory: 32,000 current readings Logging Interval: 1 seconds to 12 hours Operating Temperature Range: -35 to 80°C (-31 to 176°F) Alarm Thresholds: High/low alarm thresholds selectable in software Start Date/Time: Selectable in software Status Indicators (LEDs): Red and green Power: ½ AA 3.6 V lithium battery (included) Battery Life: 1 year typical (depends on sample rate, ambient temperature and use of alarm LEDs) Weight: 57 g (2 oz) Dimensions: See dimensional drawing | ![]() |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
Rated 5 out of
5
by
tarzu from
Cool Product.
Very easy to set up. I was able to follow the instructions and have the loggers ready to go very quickly.
Date published: 2016-09-20
Rated 4 out of
5
by
SYollis from
Excellent value, does what was advertised
Easy to use logger, software provided on a CD.
Pros very easy to use program, small unit, Omega's service is excellent
Cons, the usb cover on one unit split just from putting it on, but I think it's more for looks than protection. If you don't have a CD drive that could be a problem. The logger must be restarted every time you read it so you can't get short term readings out of it and have a long log at the same time.
Not a pro or con, the program allows you to set the logging frequency to times as short as 10 seconds. I almost can't imagine the sensor being able to register an air temperature change though it's case, in that short time.
Date published: 2017-01-12
Rated 5 out of
5
by
Linear Guy from
Great results with zero setup
Have been collecting battery discharge data every 5-minutes for two weeks with no problems, no setup and great graphical results.
Date published: 2017-12-31
Rated 1 out of
5
by
Andrea from
Poor Battery - Doesn't work in Freezer
The battery died within 48 hours of being in a -20 freezer. The device is advertised to work down to -35C. Not as described at all.
Date published: 2018-05-14
Rated 5 out of
5
by
Steve Cz from
A fine addition to a Quality Engineer's toolbox
I needed a data logger to better understand the ambient conditions of in-process product, final product in storage and final product in transit to our customers. The OM-EL-USB fit the need perfectly.
And software is simple, effective and free.
Overall, an outstanding product. Thank you Omega.
Date published: 2017-07-28
Rated 5 out of
5
by
Frank from
Good Sensor/logger Package
Simple and easy to use software, but provides enough flexibility to allow for delay deployment, and high/low alarms. I have the temp and humidity version. Two currently installed in an outdoors environment, but semi-protected from direct rain and sunlight. Time will tell how they will hold up, but not really designed for using outdoors. So far, very happy.
Date published: 2017-05-31
I have an om-el-usb 1lcd. I have download the software but am unable to get the software to find the usb stick. i't won't install the usb driver
Thank you for your question. A low battery under 3.6 volts is a possible connection problem and driver install is being prevented by PC security/firewall. If problem still persists please e-mail DAS Engr-DAS@OMEGA.COM
Date published: 2020-09-23
How often do these need to be calibrated and how much is it to calibrate them?
Calibration is not economically feasible. If units read out of tolerance than it is best to trade-in for new and get a 20% discount.
Thank you.
Date published: 2019-07-18
Can this be used in a water bath or sanitation parts washer?
Thank you for your question. The logger is not designed to be submerged in any type of fluid. It is designed for ambient temperature.
Date published: 2023-02-28
I have several OM-EL-USB-1 but the software seems to not be compatible with 64 bit PC. Do you have updated software for contemporary PCs? Thank you
Thank you for your question. The version 7.5 Easylog software download from the product page is compatible with 64 bit PC.
Date published: 2024-08-14
Is software included with purchase? Also is battery replaceable or rechargeable?
Thanks for connecting with us. Each data logger is supplied with Windows software on CD-ROM, operator’s manual and 3.6V lithium battery. Data logger plugs directly into computer’s USB port (no USB cable required). The battery is replaceable and the part number is OM-EL-BATT.
Date published: 2019-05-28
Hello! Is it certified as calibrated when I received my order?
Hello Madeleine
If you require a certificate of calibration along with the device, the part number you need to order is OM-EL-USB-1-NIST, which is the same logger only it also includes the certificate of calibration.
Date published: 2021-03-04
Is there an answer to Real Brasil's question from 2 years ago? I'm having the exact same issue. No USB driver. Cannot connect device to Windows 10 laptop using v7.5 software
“We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM”
Date published: 2022-06-13
How many hours of Data can be stored?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2023-12-22