Welcome to our new website, found an issue or bug? Please report it here

PX35
Pressure Transducers with Premium Temperature Compensation
Models In Stock
- Absolute and Gage Pressure, 15 to 30,000 psi
- Premium Temperature Compensation
- All Stainless Steel Construction
- Hermetically Sealed for Harsh Environments
PX35
From
$
370.91
Models In Stock

Product Overview
- Accuracy ± 0.25 %
- Accuracy Class 0.1% to 0.25%
- Accuracy Note 0.25% linearity, hysteresis and repeatability combined
- Burst Pressure Note 300% of rated pressure
- Compensated Temperature, Max 71 °C
- Compensated Temperature, Min 16 °C
- Electrical Output 3 mV/V
- Electrical Output Note 3 mV/V nominal
- Input Resistance 350 Ω
- Materials, Wetted 17-4 Stainless Steel
- Operating Temperature, Max 149 °C
- Operating Temperature, Min -73 °C
- Output Resistance 315 Ω to 530 Ω
- Supply Power Note 10 Vdc (15 V maximum)
- Supply Voltage 10 Vdc
- Thermal Effect on Span error, Max 0.0054% rdg/°C
- Thermal Effect on Zero error, Max 0.0054% rdg/°C, 0.008% FSO/°C
- Zero/Balance Error ± 2.0% FSO
OMEGA’s PX35 is a high-accuracy, millivolt output, industrial pressure transducer. It can be ordered with a hermetically sealed gage, making it suitable for the harshest environments. The PX35 is available in gage, sealed gage, and absolute models. Three meters (10') of 4-conductor shielded cable is standard. A twist-lock-connector electrical termination is also available.
SPECIFICATIONS
Excitation: 10 Vdc (15 V max)
Output: 3 mV/V nominal
Accuracy: 0.25% linearity, hysteresis and repeatability combined
Zero Balance:± 2.0% FSO
Input Resistance: 350 Ω min
Output Resistance: 315 to 530 Ω
Operating Temp Range: -73 to 149°C (-100 to 300°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Span: 0.003% rdg/°F
Zero: 0.004% FSO/°F
Proof Pressure: 150% of rated pressure
Burst Pressure: 300% of rated pressure
Wetted Parts: 17-4 PH stainless steel
Pressure Port:
<10,000 psi: ¼-18 NPT internal
≠¤10,000 psi: 9⁄16-18, ¼' HP tube
Electrical Connection: 3 m (10') 4-conductor cable
Show Ratings & Reviews
How is the accuracy of this transducer stated? it says 0.25%...Is that % of reading,% of full scale or is it linearity for best fit straight line? I am pairing this with a DP25B panel meter and am trying to ascertain the total system accuracy spec.Thanks
But is it 0.25% of Full Scale or 0.25% of Reading?
Date published: 2022-08-19
Is 5VDC enough to operate this sensor?
Thank you for your inquire.
The specs state
Excitation: 10 Vdc (15 V maximum)
You may try to use at 5 but can not guaranty that the accuracy will hold.
You will also get half the output.
Date published: 2022-09-01