MSXP-W12-PA

wall mount, universal current/voltage outputs, uni-directional, range 2 (600, 750, 1000, 1250 PA).

$238.00

Item# MSXP-W12-PA

In Stock

Lead Time (If not in stock): 2 weeks

Product Specs

<< See all Product Models
Brand
Accuracy ± 1 %
Accuracy Note ± 1% FSO
Burst Pressure 6 psi Maximum
Compliance CE
Display Type N/A
Electrical Connection 1/2 NPS female Conduit with Screw Terminal block
Electrical Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
Enclosure Ratings IP66, NEMA Type 4X, UL94 V-0, UL 2043 (Plenum)
Long Term Stability ± 1% FSO/year
Loop Resistance Current Output: 0 to 1250 Ω max, Voltage Output: Load resistance 1 kΩ min.
Material Construction Option N/A
Materials, Wetted Consult Factory
Media Compatibility Air, Argon, Carbon dioxide, Helium, Nitrogen, Non-Conductive Gases, Non-Corrosive Dry Gases
Mounting Note Not Position Sensitive
Mounting Orientation Wall Mount
Number of Wires 2, 3
Operating Temperature, Max 70 °C
Operating Temperature, Min -20 °C
Output Detail Field Selectable
Output Signal Current, Voltage
Power Consumption max 21 mA
Pressure Type Differential
Pressure, Max 1250 Pa
Pressure, Min 0 Pa
Process Connection Size 1/8 in, 3/16 in, 1/4 in
Process Connection Type Stepped Barb Fitting
Proof Pressure Up to 6 psi
Response Time 3 s
Response Time Note Instantaneous (default) or 3 s (selectable)
Span Adjustment Push Button
Supply Power Type AC/DC
Supply Voltage 2-Wire: 10 to 36 Vdc, 3-Wire: 17 to 36 Vdc/21.6 to 33 Vac
Weight 230 g
Wire Gauge 26 to 16 AWG
Zero Setting Adjustable Range Digital push-button
See All Specs Show Less