Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

RECU-GECU-TECU

RTD and Thermistor Extension Cables

Models In Stock
  • Retractable Coil Cord Cable in 1 and 4 ft. Lengths with 5:1 Stretch
  • 24 Gage PFA Coated or Glass Overbraid Stranded Copper Wire in 10 and 25 ft. Lengths
  • 3-Wire Copper Leads are standard
  • Standard Size or Mini Quick Connectors
RECU-GECU-TECU
From $ 29.28
Models In Stock
RTD and Thermistor Extension Cables RECU-GECU-TECU RECU-GECU-TECU
loading all models
Product Overview
  • Additional Features 1 None
  • Alloy Material (-) Copper
  • Alloy Material (+) Copper
  • Cable Type Insulated Thermocouple Extension
  • Number of Conductors 3
  • Operating Temperature, Max 782 °C
  • Operating Temperature, Min -73 °C
  • Overbraiding Type None
  • Special Limits of Error No
  • Temperature Sensor Type RTD or Thermistor
  • Wire Gauge 26 AWG
  • Wire Type Stranded
Omega offers various RTD extension cables for interconnecting RTD sensors with instrumentation. They come in either straight or retractable coil configurations,with glass braided or PFA insulating jackets. The retactable coil cord cables come in either 1 foot or 4 foot retracted lenghts that can stretch to 5 feet or 20 feet respectively.Ten termination types are available.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Which products do these pair with? Which RTD wires and data loggers?

Asked by: KMehne
Many customers use these connectors/extension cables for extending standard RTD wire such as our EXTT-3CU series shown here: https://www.omega.com/en-us/wire-and-cable/thermocouple-and-rtd-wire-and-cable/p/EXGG-2CU-3CU-WIRE. Dataloggers which can take the stripped end input include our OM-SQ series, part no. OM-CP-RTDTEMP101A and OM-CP-RTDTEMP2000 loggers. We do not have any meters/loggers that currently take the MTP series mini connectors or the OTP series standard connectors in which these cables terminate. However, the stripped-end version of these extension cable can attach to the aforementioned instrumentation and others that we offer.
Answered by: dennis882
Date published: 2020-01-23

What are the hole sizes and dimensions between holes for mounting TECU25-OTP-U-M-OTP-U-F?

Asked by: Steve468
Please contact our Temperature Department at temp@omega.com regarding this request
Answered by: Application Engineer CB
Date published: 2024-10-29
  • y_2025, m_2, d_19, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_GECU10-MTP-U-M-MTP-U-F, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 50ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration