Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

TX12-Head-Mnt-Temp-Tx

RTD Head Mount Temperature Transmitter w/ User Trim

Models In Stock
TX12-Head-Mnt-Temp-Tx
From $ 163.55
Models In Stock
RTD Head Mount Temperature Transmitter w/ User Trim TX12-Head-Mnt-Temp-Tx TX12-Head-Mnt-Temp-Tx
loading all models
Product Overview
  • Accuracy ± 5 µA
  • Accuracy Note (mA output/2000) or 5 uA (whichever is the greater)
  • Approvals BS EN 61326 ; 1998 – Electrical equipment for measurement and control ANNEX A ; ANNEX F
  • Calibration Pushbutton
  • Diameter 43 mm
  • Electrical Connection Screw Terminal
  • Electrical Output 4 to 20 mA
  • Height 21 mm
  • Humidity Range 10 to 90% RH non condensing
  • Input Accuracy ± 0.1 °C
  • Lead resistance effect 0.002°C/Ω
  • Lead Resistance, Max 20 Ω per leg
  • Operating Temperature, Max 85 °C
  • Operating Temperature, Min -40 °C
  • Output Load [(Vsupply-10)/20] kΩ
  • Probe Length 0 mm
  • Programmable Functions offset, Range, Sensor Burnout Indication
  • Response Time 1 sec
  • Self Heating Effect 0.2 uA/V
  • Sensor Type Transmitter
  • Setup Controls Pushbutton, Program LED will flash in bursts
  • Sheath Material N/A
  • Span, Min 25°C
  • Start Up Time I out < 4 mA during start up
  • Storage Temperature, Max 90 °C
  • Storage Temperature, Min -50 °C
  • Supply Current <200 µA
  • Supply Power Type DC
  • Supply Voltage 10 to 30 Vdc
  • Temperature Input Range -200 to 850°C
  • Thermal Effects 1 uA/°C, 25 ppm/°C
  • Update Rate, Max 500 ms
  • Warm Up Time 1 min to full accuracy
  • Weight 31 g
The TX12 head mounted temperature transmitter connects to any standard pt100 resistance sensor and converts the linearized temperature to a 4 to 20 mA signal. The transmitter is a two wire device, and is fully configurable by the user, over a wide temperature range, with the aid of a simple push button. This new TX12 design incorporates additional configuration menus, allowing the user to push button trim the transmitter output at both zero and span, ideal for trimming out sensor errors. The transmitters advanced circuitry guaranties high stability over the wide operating ambient temperature ranges experienced by head mounted devices. One of the transmitters features is the program LED, which provides visual indication of sensor fault when in normal operation and is also used to guide the operator through the simple menus during configuration.

SPECIFICATIONS
Input
Sensor Type: Pt100 100 Ω @ 0°C 2 or 3 Wire
Sensor Range: -200 to 850°C (-328 to 1562°F)
Sensor Connection: Screw terminal
Minimum Span: 25°C (77°F)
Linearisation: BS EN 60751(IEC 751) standard/JISC 1604
Measurement Accuracy: 0.1°C ±0.05% of reading
Thermal Drift: 25 ppm/°C
Excitation Current: <200 uA
Lead Resistance Effect: 0.002°C/Ω
Maximum Lead Resistance: 20 Ω per leg

Output
Output Type: 2 wire, 4 to 20 mA current loop
Output Range: (4.0 to 20.0) mA
Output Connection: Screw terminal
Maximum Output: 21.5 mA (in high burnout condition)
Minimum Output: 3.8 mA (in low burnout condition)
Accuracy: (mA output /2000) or 5 uA (whichever is the greater)
Loop Voltage Effect: 0.2 uA/V
Thermal Drift: 1 uA /°C
Maximum Output Load: [(Vsupply-10)/20]K Ω
(Example: 700 Ω @ 24V)

General Specifications
Update Time: 500 mS
Response Time: 1 second
Start Up Time: 4 seconds (I out < 4 mA during start up)
Warm-Up Time: 1 minute to full accuracy
Power Supply: 10 to 30 Vdc

Environmental
Ambient Operating Range: -40 to 85°C (-40 to 185°F)
Ambient Storage Temperature: -50 to 90°C (-58 to 194°F)
Ambient Humidity Range: 10 to 90% RH non condensing

Physical
Dimensions: 43 diameter; 21 mm height (1.7; 0.8")
Weight: 31 g (0.068 lb) (encapsulated)
Approvals
EMC - BS EN 61326 :1998: Electrical equipment for measurement control and laboratory use
ANNEX A: Immunity test requirements for equipment intended for use in industrial locations
ANNEX F: Test configurations, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61000-4-2: Electrostatic discharge
IEC 61000-4-3: EM field
IEC 61000-4-4: Transient burst (output)
IEC 61000-4-5: Surge (output)
Note: Sensor input wires to be less than 3 m to comply.
Rated 5 out of 5 by from TX12 rtd amplifier digital adjust zero and span We used these rtd amplifiers periodically to integrate into systems for resale. I find them superior because we can adjust the zero and span over a wide range of temperatures for various system needs with a relatively simple setting procedure - unlike other types which have a very narrow adjustment band. We use a simple fixed resistance reference set and get accuracy better than +-.25 deg C accuracy with our thin film rtds.
Date published: 2016-02-26
Rated 5 out of 5 by from Fast support and shipping! Omega got me out of a jam with this transmitter. It worked great. Easy to program
Date published: 2020-05-19
  • y_2025, m_2, d_21, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_TX12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

is it supported with PR-12L RTD

Asked by: Athar99
The TX12 Transmitter can be installed in all of the PR-12 assemblies L,H or E.
Answered by: Applications Engineer AB
Date published: 2022-03-14
  • y_2025, m_2, d_20, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_TX12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration