CL3512A-Series
Rugged J,K,T, E Thermocouple Calibrator and Thermometer
Models In Stock
- 8-Point, NIST-Traceable Calibration Certificate
- Large 31/2 Digit Display
- Type J/K/T/E TC Calibrator and Thermometer
- Range -220 to 1372°C (-364 to 1999°F)
CL3512A-Series
From
$
377.96
Models In Stock

Product Overview
- Accuracy ± 0.1 %
- Accuracy Detail ± (0.1% rdg + 1°C) Accuracy is specified for operating temperatures from 18 to 28°C (64 to 82°F), for 1 year, not including thermocouple error; ± (0.1% rdg + 1°C) range -60 to 1372°C [± (0.1% rdg + 2°F) range -76 to 1999°F] ± (0.1% rdg + 2°C) range -60 to -220°C[± (0.1% rdg + 4°F) range -76 to -364°F]
- Auto-Ranging 0.1° to 1°
- Auto-Ranging Note 0.1° to 1° resolution above 199.9 (°C or °F)
- Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
- Battery life 100 hr
- Display Type LCD
- Display Type Note 3 1⁄2 digit LCD with a maximum reading of 1999. Overrange: (-OL) is displayed. Zero: Automatic
- Height 195 mm
- Length 53 mm
- Operating Temperature, Min 0 °C
- Operating Temperature Note 0 to 50°C (32 to 122°F) @ <80% RH
- Polarity Automatic, positive implied, negative polarity indication
- Relative Humidity, Max 0.8
- Relative Humidity, Min 0%
- Resolution, Max 1 °C
- Resolution, Min 0 °C
- Resolution Note 0.1 (to 199.9) or 1°
- Sampling Rate 1 Hz (1 update/second)
- Simulation Accuracy Measurement Accuracy + 1°C
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Storage Temperature Note -20 to 60°C (-4 to 140°F), 0 to 80% RH with battery removed from meter
- Supply Voltage 9 Vdc
- Thermocouple Type J, K, T, E
- Type of RTD Signal None
- Weight 250 g
- Weight Note Approximately 250 g (9 oz)
- Width 92 mm
The OMEGA CL3512A handheld calibrator is two meters in one at an attractive low price. The CL3512A is a temperature calibrator, or thermocouple calibrator, that simulates type J/K/T/E thermocouple signals. Each signal is adjustable by using the coarse and fine dials. The CL3512A can also be used as a dual type J/K/T/E input thermocouple thermometer. Features include a large 3 1/2 digit display with backlighting and display selections of HOLD, °C/°F, and 0.1°/1°.
SPECIFICATIONS
Thermocouple Type: J/K/T/E
Temperature Range: Celsius or Fahrenheit User
Selectable Measurement Ranges: K-Type -200 to 1372°C (-328 to 1999°F), J-Type -210 to 1200°C (-346 to 1999°F), T-Type -200 to 400°C (-328 to 752°F), E-Type -220 to 1000°C (-364 to 1832°F)
Calibration Range: Same as measurement range Auto Range: 0.1° to 1° resolution above 199.9 (°C or °F)
Measurement Accuracy: Accuracy is specified for operating temperatures over the range of 18 to 28°C (64 to 82°F), for 1 year, not including thermocouple error. ± (0.1%rdg + 1°C) range -60 to 1372°C ± (0.1%rdg + 2°C) range -60 to -220°C ± (0.1%rdg + 2°F) range -76 to 1999°F ± (0.1%rdg + 4°F) range -76 to -364°F
Read More
SPECIFICATIONS
Thermocouple Type: J/K/T/E
Temperature Range: Celsius or Fahrenheit User
Selectable Measurement Ranges: K-Type -200 to 1372°C (-328 to 1999°F), J-Type -210 to 1200°C (-346 to 1999°F), T-Type -200 to 400°C (-328 to 752°F), E-Type -220 to 1000°C (-364 to 1832°F)
Calibration Range: Same as measurement range Auto Range: 0.1° to 1° resolution above 199.9 (°C or °F)
Measurement Accuracy: Accuracy is specified for operating temperatures over the range of 18 to 28°C (64 to 82°F), for 1 year, not including thermocouple error. ± (0.1%rdg + 1°C) range -60 to 1372°C ± (0.1%rdg + 2°C) range -60 to -220°C ± (0.1%rdg + 2°F) range -76 to 1999°F ± (0.1%rdg + 4°F) range -76 to -364°F