1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
LC60
Single Point Load Cell with IP65 Rating
Models In Stock
- Aluminum-Alloy IP65 Single Point Load Cell.
- Colorless Anodized Aluminum

Product Overview
- Approvals OIML R60
- Cable Length 1.5 ft
- Dead load 0% FS
- Electrical Connection Cable
- Enclosure Ratings IP65
- Input Resistance 406 ± 6 Ω
- Insulation Resistance ≥ 5000 MΩ
- Load Cell Type Bending Beam
- Operating Temperature, Max 65 °C
- Operating Temperature, Min -35 °C
- Output Resistance 350 ± 3 Ω
- Overload, Max 150% FS
- Process Temperature, Max 40 °C
- Process Temperature, Min -10 °C
- Safe Overload 120% FS
- Storage Temperature, Max 70 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 5 to 12 Vdc, 18 Vdc max
- Supply Voltage 5 to 12 Vdc
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
Omega’s LC60 Series is a low cost, highly accurate, single point load cell, ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading, allowing direct mounting to the scale base and weighing platform. The LC60 Series features a moisture-proof sealant and is available in ranges from 600 grams to 200 kilograms.
Maximum Platform Size:
LC61SP: 200 x 200 mm (7.87 x 7.87") LC62SP: 250 x 350 mm (9.84 x 13.77") LC63SP: 400 x 400 mm (15.74 x 15.74")
Specifications
LC62 and LC63: C3
OIML R60 Accuracy Class: LC61: C3D
Output Sensitivity (= FS, mV/V):
LC61: 1.0 ± 0.1
LC62 and LC63: 2.0 ± 0.2
Maximum Number of Load Cell Intervals(nLC):
LC61: 2500
LC62 and LC63: 3000
Ratio of Minimum LC Verification Interval Y = Emax/vmin:
LC61: 5000
LC62 and LC63: 10000
Combined Error:
LC61: ± 0.028 %FS
LC62 and LC63: ± 0.02 %FS
Minimum Dead Load: 0% FS
Safe Overload: 120% FS
Maximum Overload: 150% FS
Zero Balance: ± 2.0% FS
Excitation, Recommended Voltage: 5 to 12 VDC
Excitation Maximum: 18(VDC)
Input Resistance ?: 406 ± 6
Output Resistance ?: 350 ± 3
Insulation Resistance M?: ? 5000 (50 VDC)
Compensated Temperature: -10 to 40ºC (14 to 104ºF)
Operating Temperature: -35 to 65ºC (-31 to 149ºF)
Storage Temperature: -40 to 70ºC (-40 to 158ºF)
Element Material: Aluminum
Recommended Bolt Size/Torque (Nm):
LC61: M3/1.5
LC62: M6/6 for < 30kg, M6/10 for > 30kg
LC63: M6/10
Ingress Protection (According to EN 60529): IP65
Figure 1 All Dimensions mm
Figure 2
Figure 3
Wiring
Read More
Maximum Platform Size:
Specifications
LC62 and LC63: C3
OIML R60 Accuracy Class: LC61: C3D
Output Sensitivity (= FS, mV/V):
LC61: 1.0 ± 0.1
LC62 and LC63: 2.0 ± 0.2
Maximum Number of Load Cell Intervals(nLC):
LC61: 2500
LC62 and LC63: 3000
Ratio of Minimum LC Verification Interval Y = Emax/vmin:
LC61: 5000
LC62 and LC63: 10000
Combined Error:
LC61: ± 0.028 %FS
LC62 and LC63: ± 0.02 %FS
Minimum Dead Load: 0% FS
Safe Overload: 120% FS
Maximum Overload: 150% FS
Zero Balance: ± 2.0% FS
Excitation, Recommended Voltage: 5 to 12 VDC
Excitation Maximum: 18(VDC)
Input Resistance ?: 406 ± 6
Output Resistance ?: 350 ± 3
Insulation Resistance M?: ? 5000 (50 VDC)
Compensated Temperature: -10 to 40ºC (14 to 104ºF)
Operating Temperature: -35 to 65ºC (-31 to 149ºF)
Storage Temperature: -40 to 70ºC (-40 to 158ºF)
Element Material: Aluminum
Recommended Bolt Size/Torque (Nm):
LC61: M3/1.5
LC62: M6/6 for < 30kg, M6/10 for > 30kg
LC63: M6/10
Ingress Protection (According to EN 60529): IP65
Figure 1 All Dimensions mm

Figure 2

Figure 3

Wiring