TX60

Smart and Programmable Linearized Transmitters

Models In Stock
  • 2 Wire 4-20 mA Output
  • TX62 TX64 Models for Thermocouple and RTDs
  • TX63 TX65 Models for mV, mA, V, Resistance
  • Input to Output Isolation
TX60
From $ 427.11
Models In Stock
Smart and Programmable Linearized Transmitters TX60 TX60
loading all models
Product Overview
  • Accuracy ± 0.05 %
  • Accuracy Detail Transmitter Accuracy:±0.05% of the millivolt or Ω equivalent reading, or the accuracy from the table below, whichever is greater; plus ±0.05% of the span, if using a thermocouple sensor, allow a cold junction measurement error of ±0.5°C (±0.9°F), accuracy includes repeatability, hysteresis, load and ambient temperature Thermocouple Type: J: ±0.2°C K: ±0.2°C T: ±0.2°C E: ±0.2°C R: ±0.6°C S: ±0.6°C B: ±0.8°C N: ±0.2°C RTD Accuracy: ±0.1°C Voltage Accuracy: ±0.008 mV
  • Additional Features 1 Programmable temperature transmitter
  • Calibration Adjustment 100 % sensor range
  • CMRR 120 dB
  • Cold Junction Compensation ±0.5°C
  • Diagnostics Every 3 seconds, self-checks for zero, span, cold junction, calibration references, malfunction and sensor failure
  • Electrical Output 2-wire, 4 to 20 mA
  • EMC Immunity Note RFI Effect: <0.5% rdg (SAMA PMC 33.1c test) 20 kHz to 1000 MHz, 10 V/meter
  • Input Control Signal -15 to 160 mV
  • Isolation 850 Vdc or peak ac
  • Linearity Error ±0.05°C
  • Load Resistance 250 Ω
  • Long Term Stability < 0.05% of reading plus ±5 µA per year
  • Operating Temperature, Max 75 °C
  • Operating Temperature, Min -40 °C
  • Output Signal Current
  • Repeatability One-half of accuracy
  • Resolution ±2.5 µA
  • Response Time 0.25 sec; Update Time: 0.15 sec, digital, 1 sec
  • Response Time Note Analog 0.25 second typical; digital 1 second, typical to 95% of final value, 5 seconds to stated accuracy (Response to Step Input)
  • Reverse Voltage 42 Vdc applied with either polarity
  • RTD Type 100 Ω Pt Sensor,120 Ω Ni Sensor
  • Sensor Break Detection Analog, user settable to 21 mA, 3.9 mA or “OFF”, digital
  • Start Up Time <5 sec
  • Storage Temperature, Max 85 °C
  • Storage Temperature, Min -50 °C
  • Supply Power Note Minimum supply voltage under load, Vs = 12 + R (load in kΩ) X 23 mA; for digital operation
  • Supply Power Type DC
  • Supply Voltage 12 to 42 Vdc
  • Temperature Compensation Automatic compensation to 20°C/hour change, Self-correcting over operating temperature range
  • Temperature Measurement Range J: -210 to 1200°C, K: -270 to 1372°C, T: -270 to 400°C, E: -270 to 1000°C, R: -50 to 1768°C, S: -50 to 1768°C, B: 43 to 1820°C, N: 0 to 1300°C, RTD: -200 to 850°C
  • Thermocouple Type J, K, T, E, N, R, B, S
  • Weight 340 g
The TX60 series has been discontinued. Please see the TX86 as a possible alternative or contact our Data Acquisition Engineering department.

The TX62 and TX64 programmable transmitters provide an isolated 4 to 20 mA signal linearized to temperature or process input.

For complete product specifications see the Related Links section at the bottom of this page.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 21ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration