Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

PR-22

RTD Probes with Molded M12 Connectors

Models In Stock
PR-22
From $ C0.00
Models In Stock
RTD Probes with Molded M12 Connectors PR-22 PR-22
loading all models
Product Overview

Accessories

M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$86.20
17 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$81.57
13 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$138.63
0 In Stock
M12 Cables with Field Mountable Connectors for Resistance Sensors (RTDs)
C$89.65
14 In Stock
Rated 1 out of 5 by from Melted at 400C Probe melted at 400c, previous probe did not melt.
Date published: 2025-03-06
Rated 5 out of 5 by from PT100 are 100 We prefer this product for our assemblies. Omega has never let us down.
Date published: 2023-04-17
Rated 5 out of 5 by from Great Value Works as expected and a great value for replacement RTD's.
Date published: 2023-03-13
Rated 5 out of 5 by from Great for coffee roasters Worked great on my coffee roaster. Much more reliable data.
Date published: 2022-10-18
Rated 5 out of 5 by from Unmatched Quality I have bought these and various similar items over the years. I have never had an issue with any of them.
Date published: 2022-10-14
  • y_2025, m_4, d_18, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_PR-22-3-1000-A-1-4-0600-M12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT

Can a 4 wire rtd be connected to a 3 wire instrument 

Asked by: Atfab
A 4 wire RTD can be used for a 3 wire instrument by not using one of the sensor wires . Please contact our Temperature Group at 800-826-6342 for further wiring details
Answered by: SAT_SAE
Date published: 2020-09-09

I am using this probe in a Saline solution and seeing corrosion after a few weeks, is the 316 SS passivated? Also, is there a coating that can be applied to this sensor to make it less susceptible to corrasion? PN: PR-22-3-100-A-M2-250-M12

Asked by: dmbenmcc
Thank you for the inquiry. Please forward this request to TEMP@OMEGA.COM. We will assist you in finding cause for corrosion. best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-07-15

PR-22-3-100-A-1/8-0600-M12: (1) part # compress.fitting w/ 1/8NPT male? (2) probe min. immersion lg.? (3) is the insertion lg. adjustable, i.e. can compress.fitting be installed at any location along probe tube (plan to install.on different pipe sizes)?

Asked by: Catalin
The minimum insertion length for RTD's is 2" and yes you can place a compression fitting along the length of the probe to adjust the depth.
Answered by: ApplicationEngineerANB
Date published: 2024-12-04

What is the sensitivity (alpha in units of Ohms per degrees Celsius) for this model?

Asked by: RTDalpha
For the RTD Class A, Class A = ±(0.15 + 0.002*t)°C or 100.00 ±0.06 Ω at 0ºC
Answered by: AndrewA
Date published: 2020-08-20

Is this probe bendable?

Asked by: sfb8
The PR-22 are not bendable so look to the PR-26 if you need a bendable RTD probe.
Answered by: ApplicationEngineerANB
Date published: 2023-06-09

Can this probe be used for air measurement?

Asked by: Eli T
Thank you for the inquiry. Yes, this probe can be used for air measurement.
Answered by: NorwalkAE_SP
Date published: 2024-09-05

What are the 0-100C response times in water for this sensor? 50%, 63%, 90% etc.?

Asked by: RobW
Hi RobW, Thank you for the inquiry. Response times will be comparable to the PR-21 series. https://www.omega.com/en-us/temperature-measurement/temperature-probes/probes-with-integral-connectors/pr-21/p/PR-21A-3-100-1-3-M6-0150-M12-1 Fast Response Time (3.5 Seconds or Less 63% Response in Water). Response to near 100% would be 5x this value. Please contact temperature group for more details if needed. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-07-15
  • y_2025, m_4, d_18, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_en_US, sid_PR-22-3-1000-A-1-4-0600-M12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 9ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration