Welcome to our new website, found an issue or bug? Please report it here

NB1-ICIN-TBSL-SPRING-TC
Spring Loaded Thermocouple Probes Protection Heads
Models In Stock
- Non-sealed Design For Use With Thermowells
- Made with Special Limits of Error Thermocouple Material
- Approx. 1/2' of Travel Length
- 1/2' NPT Mounting Threads Standard
NB1-ICIN-TBSL-SPRING-TC
From
$
119.36
Models In Stock

Can't find the right model?
Use our custom configurator to fine tune your product
Product Overview
- Additional Features 1 Dual Elements
- Process Connection Size 1/2 in
- Process Connection Type NPT Male
- Process Temperature, Min 0 °C
- Temperature Sensor Type Thermocouple
These spring loaded probes are available in a range of protection head styles to meet environmental and size requirements. The spring terminal block assemblies allow for up to ½” of probe movement along the head’s axis. They are available in J, K, T, N, or E calibration and in 304 or 316 SS, Inconel 600, or OMEGACLAD™XL sheaths.
The probe length (in its relaxed state) should equal the stem (element) length of the desired thermowell. For example, a 12 inch probe will measure 12 inches from the end of the ½” hex fitting to the tip and will fit properly into a thermowell with a 12 inch stem length. There will be approximately ½ inch of compression as the probe assembly is screwed into the thermowell.
The moving internal terminal block with attached probe is standard on all models. Consult the Custom Engineering Dept. for price and delivery on a wide variety of non-metallic and other specialized heads.
View the Thermocouple Accuracy and Color Code charts
The probe length (in its relaxed state) should equal the stem (element) length of the desired thermowell. For example, a 12 inch probe will measure 12 inches from the end of the ½” hex fitting to the tip and will fit properly into a thermowell with a 12 inch stem length. There will be approximately ½ inch of compression as the probe assembly is screwed into the thermowell.
The moving internal terminal block with attached probe is standard on all models. Consult the Custom Engineering Dept. for price and delivery on a wide variety of non-metallic and other specialized heads.
View the Thermocouple Accuracy and Color Code charts
PDFs & Manuals
Show Ratings & Reviews
If ordering an NB1-CASS-14U-12-SL, is the actual probe length 11.5" (including 0.5" of NPT thread insertion)?
That is correct the probe from tip to 0.5" up the NPT threads is 12".
Date published: 2023-12-08