1-800-663-4209 | Welcome to our new website, found an issue or bug? Please report it here
TX13-Smart-Temp-Tx
Thermocouple Input Temperature Transmitter w/ Pushbutton Config
Models In Stock
TX13-Smart-Temp-Tx
From
$
215.32
Models In Stock

Product Overview
- Accuracy ± 5 µA
- Accuracy Detail (mA output/2000) or 5 uA (whichever is the greater)
- Approvals BS EN 61326 ; 1998 – Electrical equipment for measurement and control ANNEX A ; ANNEX F
- Calibration Pushbutton
- Cold Junction Compensation ±0.05°C/°C
- Cold Junction Temperature Accuracy ±0.5 °C
- Diameter 43 mm
- Electrical Connection Screw Terminal
- Electrical Output 4 to 20 mA
- Height 21 mm
- Humidity Range 10 to 90% RH non condensing
- Input Accuracy ± 0.5 °C
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Output Load [(Vsupply-10)/20] kΩ
- Probe Length 0 mm
- Programmable Functions offset, Range, Sensor Burnout Indication, sensor type
- Response Time 1 sec
- Self Heating Effect 0.2 uA/V
- Sensor Type Transmitter
- Setup Controls Pushbutton, Program LED will flash in bursts
- Sheath Material N/A
- Stability Offset: 0.1°C/°C;Span: 0.05°C/°C
- Start Up Time I out < 4 mA during start up
- Storage Temperature, Max 90 °C
- Storage Temperature, Min -50 °C
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Temperature Input Range K: -200 to 1370 °C; J: -100 to 1200 °C; E: -100 to 1000 °C; N: -180 to 1300 °C; T: -100 to 400 °C; R -10 to 1760 °C; S: -10 to 1760 °C
- Thermal Effects 1 uA/°C
- Update Rate, Max 500 ms
- Warm Up Time 1 min to full accuracy
- Weight 31 g
The TX13 in-head mounting thermocouple transmitter converts a thermocouple input over a configured range to a standard industrial (4 to 20 mA) transmission signal. A simple push button operation allows the user to select thermocouple type, burnout direction, select fixed ranges and trim 4 and 20 mA points. The in-head transmitter incorporates the latest digital technology to ensure accurate drift-free performance.
The default factory scaling is for a range of 0 to 1000°C and Type K thermocouple input, with up-scale burnout.
Specifications
The default factory scaling is for a range of 0 to 1000°C and Type K thermocouple input, with up-scale burnout.
Specifications
PDFs & Manuals