Welcome to our new website, found an issue or bug? Please report it here

OM-CP-TCTEMP2000-Logger
Thermocouple Temperature Data Logger with LCD Display
Models In Stock
- Large, Backlit LCD Display
- Accepts Thermocouple Types J, K, T, E, R, S, B, N
- Front Keypad with Lock Feature
- High Speed Download
OM-CP-TCTEMP2000-Logger
From
$
645.00
Models In Stock

Product Overview
- Battery life up to 1 yr
- Battery Size and Type Li-ion, 9V
- Calibration Digital calibration through software
- Data Interface USB
- Data Interface Note PC serial or USB (interface cable required); 115,200 baud
- Display Type LCD
- Display Type Note 63 x 35 mm
- Electrical Connection Sub-D Female Miniature Connector
- Enclosure Aluminum
- Length 122 mm
- Measurement Type Temperature
- Memory 131071
- Memory Note 131,071 readings per channel; 262,143 total readings; software configurable memory wrap
- Number of Measurements 1
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Relative Humidity Accuracy ± 3% RH
- Relative Humidity, Max 0.95
- Relative Humidity, Min 0%
- Samples,Max 130000
- Sampling Rate 0.5 Hz (2 seconds between updates)
- Sampling Rate Note 1 reading every 2 seconds to 1 every 24 hours
- Software Compatibility Windows® XP/VISTA/7 and 8 (32- and 64-bit)
- Start Modes Adjustable Delay Start
- Supply Power Type Battery
- Temperature Accuracy ± 0.5 °C
- Temperature Measurement, Max 60 °C
- Temperature Measurement, Min -20 °C
- Temperature Resolution ± 0.1 °C
- Time Accuracy ± 1 minute/month (at 20 to 30°C)
- Weight 440 g
- Width 84 mm
Description
The OM-CP-TCTEMP2000 is a battery powered thermocouple temperature data logger with an LCD display. This data logger has an internal temperature sensor and one external input for J, K, T, E, R, S, B, and N type thermocouples. The 8-button keypad and large LCD provide convenient access to current data and recorder setup. Additionally, memory and battery levels, external power status, and sampling and recording status are shown on the LCD.Available on-screen data includes: statistics (min, max, average) recording status (start, stop and recording rate) display options (units, text size) and calibration information (date calibrated, date for recalibration). Statistics can be cleared at any time during logging. With 131,071 readings, the OM-CP-TCTEMP2000 has one of the largest memory capacities of any similar data recorder on the market. The non-volatile memory will retain recorded data, even if AC and battery power are lost. The OM-CP-TCTEMP2000 runs on a 9 V battery with a typical battery life of 1 year at a 1 min reading rate with the display off. With continuous LCD and no backlight usage, the average battery life is 30 days. For power savings, both the LCD and backlight have configurable auto-off options.
Those wanting to keep the LCD display and backlight continuously active need only to connect the unit to an AC power supply, keeping the 9 V battery connected as a back-up. NIST traceable calibration is available for users needing to meet regulatory requirements. Creating permanent records, performing data calculations, and the graphing of data is quick and easy: Simply connect the interface cable to an availableUSB or serial port and, with a few clicks of the mouse, data is downloaded and ready for review or export to Excel.
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews
How do you change TC Type?
Hi, thermocouple type can be changed during set up of the logger through the software. When you set up the logger to start recording you can change sampling rate, start/stop method and thermocouple type among other parameters. Interface cable and software package is sold separately. If you don't already have one you might consider buying one OM-CP-IFC200. Thank you for taking us into consideration for your application needs.
Date published: 2019-06-20
How do you shut it off? The manual is not available
Thank you for your question. There is no shut off button. You can only stop logger from logging from the software. Please see link to download 2 manuals for the logger.
https://www.omega.ca/en/pdf-manuals
Date published: 2022-09-28