RD5100-Series
Universal Input 10 in (250 mm) Hybrid Chart Recorder
Models In Stock
- High Speed Scanning at 36 Points/Sec and High-Speed Recording
- High Accuracy of 0.05%
- Various Industrial Values Can be Measured at the Same Time with Selectable Ranges
- Superior Ease of Operation
RD5100-Series
From
$
8,915.61
Models In Stock

Product Overview
- Accuracy ± 0.05 %
- Accuracy Note Thermocouple K: ±0.05% ±0.5°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), E: ±0.05% ±0.7°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), J: ±0.05% ±0.7°C (±20 mV, ±40 mV), ±0.05% ±1°C (±80 mV), T: ±0.05% ±0.7°C (±20 Mv), R,B: ±0.05% ±1°C (±20 Mv), U,L: ±0.05% ±1°C, W-WRe26, PrRh40-PtRh20, NiMo-Ni: ±0.1% ±1°C, N: ±0.1% ±0.1°C, Platinel II: ±0.1% ±0.1°C (±20 Mv), ±0.1% ±1°C (±40 mV, ±80 mV), RTD: ±0.05% ±0.3°C, DC Voltage: ±0.05% ±1 digit
- Alarm Note Alarm Types: High limit, low limit, Alarm Setting Method: Individual setting for each point four levels/ channels
- Battery life up to 5 yr
- Battery Size and Type Li-ion
- Chart Length 20000 mm
- Chart Note Fan-fold type; overall width 318 mm (12.5"), total length 20 m (65.6'); effective recording width 250 mm (10") (analog recording)
- Chart Speed 1 to 1,500 mm/h
- Chart Width 250 mm
- CMRR 130 dB
- Common Mode Voltage 30 Vac
- Cutout Dimensions 388 x 248 mm
- Dielectric Strength Between Primary Terminals and Protective Conductor Terminals: 1 minute at 1500 Vac, Between Secondary Terminals and Protective Conductor Terminals:1 minute at 500 Vac, Between Primary Terminals and Secondary Terminals: 1 minute at 1500 Vac
- Display Note Color LCD panel RGB (640 x 240 dot), Size: 149.8 W x 57.4 mm H, Setting Display: Common to digital display Display Contents: Digital display, Channel Display: One-point/multiple points continuous/sequential indication change, Display Measuring Value of Each Channel: One-point/multiple points continuous/sequential indication change, Clock Display: Hour/Minute/ Second/Tag/Unit. Alarm Display: Occurrence CH No, data is displayed in red when alarm occurs
- Display Type LCD
- Electrical Connection Note Terminal Board: Detachable type, removable for wire connection
- Height 260 mm
- Input Note Input Correction: Zero/span correction and shift correction for each channel
- Input Resistance 1 MΩ
- Insulation Resistance Between Primary Terminals and Protective Conductor Terminals:20MΩ or more at 500 Vdc, Between Secondary Terminals and Protective Conductor Terminals: 20MΩ or more at 500 Vdc, Between Primary Terminals and Secondary Terminals: 20MΩ or more at 500 Vdc
- LED Indicators Record On: Lights during recording; LED, Key Lock: Lights during key lock, Alarm: Lights during alarm activated; LED, Chart End: Lights just before record ending, Fail: Lights during unit abnormal time
- Length 300 mm
- Loop Resistance, Max Thermocouple Inputs, DC Voltage Input (10 mV): 500Ω or less (without burnout), DC Voltage Input (Except 10 mV): 100Ω or less Resistance, Thermometer Inputs: 10Ω or less/ line, three lines are common, Pt100, JPt100
- Materials ABS, Soda glass, Steel
- Measurement Range Note Thermocouple: K: Reference Range: ±20 mV: -200 to 500°C, ±40 mV: -200 to 900°C, ±80 mV: -200 to 1370°C, E: Reference Range: ±20 mV: - -200 to 250°C, ±40 mV: -200 to 500°C, ±80 mV: -200 to 900°C, J : Reference Range: ±20 mV: - -200 to 350°C, ±40 mV: -200 to 700°C, ±80 mV: -200 to 1200°C, T: Reference Range: ±20 mV: - -200 to 400°C, R: Reference Range: ±20 mV: 0 to 1760°C, B: Reference Range: ±20 mV: 0 to 1300°C, N : Reference Range: ±20 mV: 0 to 600°C, ±40 mV: 0 to 1000°C, ±80 mV: 0 to 1300°C, W-WRe26: Reference Range: ±80 mV: 0 to 2315°C, W-WRe26: Reference Range: ±80 mV: 0 to 2315°C, PtRh20-PrRh40: Reference Range: ±20 mV: 0 to 1888°C, U : Reference Range: ±20 mV: -200 to 350°C, ±40 mV: -200 to 600°C, L : Reference Range: ±20 mV: -200 to 350°C, ±40 mV: -200 to 700°C, ±80 mV: -200 to 900°C, Nimo-Ni: Reference Range: ±80 mV: -50 to 1310°C, Platinel II: Reference Range: ±20 mV: 0 to 500°C, ±80 mV: 0 to 950°C, 0 to 1395°C RTD: Reference Range: 50Ω: -50 to 50°C , 100Ω: -100 to 130°C, 200Ω: -200 to 250°C, 300Ω: -200 to 550°C Voltage: ±10 mV, ±20 mV, ±40 mV, ±80 mV, ±1.5 V, ±2.5 V, ±5 V, ±10 V
- Measurement Type Thermocouple, RTD, Voltage
- Mounting Panel Mount
- NMRR 50 dB
- Operating Environment Reference Operating Condition: Ambient Temperature/Humidity Range: 21 to 25 °C (70 to 77°F), 45 to 65% RH,Power Voltage: 90 to 264V,Power Frequency: 50/60Hz ±2%,Attitude: Forward/Backward/left/right within 3°,Warm-Up Time: 1 hour or longer; Normal Operating Condition: Ambient Temperature/Humidity ,Range: 0 to 40 °C (32 to 104°F), 20 to 80% RH,Power Voltage: 90 to 264V,Power Frequency: 50/60Hz ±2%,Attitude: Forward/backward/left/right within 3°
- Operating Temperature, Max 40 °C
- Operating Temperature, Min 0 °C
- Power Consumption 100 VA
- Recording Color Analog Recording: Red, Purple-Red, Orange, Brown, Green, Yellow-Green, Blue-Green, Purple, Purple-Blue, black, Digital Recording and Logging: Black
- Recording Note Recording System: Raster scan system, 10-color wire dot printing; Compensation: Independent setting of zero spans are available, Operation: Record On/Off: Recording operation ON/OFF*, Data Print: Printing measuring data*, Feed: Fast-forwarding chart paper
- Relative Humidity 20 to 80% RH
- Resolution Input: 1/40,000; Display: Thermocouple, RTD: 0.1°C, DC Voltage: 1 µV(±10 mV, ±20 mV), 10 µV(±40 mV, ±80 mV), 100 µV(±1.25V, ±2.5V), 1 mV(±5V, ±10V)
- RTD Type 100 Ω pt or Jpt sensor; 3-wire Pt100
- Sampling Rate 0.1 sec/channel
- Sensor Break Detection Thermocouple Burn-Out: Select with/without burnout for each input
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Supply Power Note Power Voltage: 90 to 264V, Power Frequency: 50/60Hz ±2%
- Supply Power Type AC
- Supply Voltage 100 to 240 Vac
- Switch Rating 3 A @ 100 to 240 Vac
- Switch Rating Note 100 to 240 Vac, 3 A resistance load
- Switch Type SPST NO
- Temperature Drift 0.1%/10°C
- Temperature Measurement Range K: -200 to 1370°C, E: -200 to 900°C, J: -200 to 1200°C, T: -200 to 400°C, R: 0 to 1760°C, B: 0 to 1300°C, N: 0 to 1300°C, W-WRe26: 0 to 2315°C, B: 0 to 1888°C, L: -200 to 900°C, Nimo-Ni: -50 to 1310°C, Platinel II: 0 to 1395°C, RTD: -200 to 550°C
- Thermocouple Type J, K, T, R, S, N, E, Platinel II, WRe5-WRe26, NiMo-Ni, U, L
- Transportation and Storage Details Transportation Condition: Ambient Temperature/Humidity ,Range: -20 to 60°C (-4 to 140°F), 5 to 90%RH (no dew condensation),Vibration: 10 to 60 Hz, 4.9 m (16')/ S2 (0.5G or less),Impact: 392 m (1.3')/S2 (approx. 40G or less); Storage Condition: Ambient Temperature: -20 to 60°C (-4 to 140°F), 5 to 90% RH (no dew condensation),
- Voltage Measurement Range ± 10 mV, ± 20 mV, ± 40 mV, ± 80 mV, ± 1.5 V, ± 2.5 V, ± 5 V, ± 10 V
- Weight 15 kg
- Width 400 mm
RD5100 series chart recorders are 250 mm (10") hybrid recorders with multi-range input. Innovative design high performance recorder provides high accuracy, ±0.05% high speed scanning, 0.1 second for 36 points and high speed recording, 1 line in 3 seconds. Simple operational keys and PC setting functions drastically improved usability of recording system.