OMB-DAQ-55

USB Data Acquisition Modules for Thermocouples Process Signals

$1,678.75

Item# OMB-DAQ-55

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $1,678.75
5-9 $1,594.81
10-24 $1,561.24
25-49 $1,494.09
50-99 $1,460.51
100+ $1,426.94

Product Specs

<< See all Product Models
Brand
A/D Conversion 22-Bit A/D
Accuracy ± 0.5 °C
Analog I/O Note Analog Input Note: Analog Specifications;Each channel is configurable for single-ended or differential, Volts, or thermocouple inputs;Thermocouple Accuracy;In very slow mode, 22 bit resolution, includes cold junction compensation error;J (±1.1°C), K (±1.2°C), T (±1.1°C); E (±1.0°C), R (±2.5°C), S (±2.6°C), B (±3.3°C), N (±1.5°C);Cold Junction Compensation Accuracy: (±0.5°C),;Over-Voltage Protection: ±45 V relative to analog Lo;AC Common Mode Rejection: >120 dB @ 60 Hz;Channel-to-Channel Crosstalk: <-120 dB (DC to 100 Hz);;Accuracy;OMB-DAQ-55/56: 0.015% of reading +0.002% of range (exclusive of noise);Input Resistance: >10 M Ohm (SE), >20 M Ohm (DE);Bias Current: <1 nA (0-35°C)
Bandwidth DC to 1 MHz
CMRR >120 dB @ 60 Hz
Configuration Parameters Open-Collector Driver, Schmitt-Trigger Input, User-Configurable Input/Output
Data Interface Ethernet
Data Interface Note Supported Operating System: Microsoft Windows®XP SP2 / VISTA/7
Digital I/O Note Digital Output Maximum Switch Voltage:0 to +15 Vdc (20 V for <1 minute) Maximum Switch Current: 150 mA/output continuous, 500 mA/output peak (<100 µs),150 mA total continuous (per bank of 8 outputs) Output Resistance: 10 Ohms max;Cross talk: <-120 dB (DC to 100 Hz);Sink Current: 150 mA
Digital Input Digital: Low <1.3 Vdc
Height 45 mm
Input Configuration Connected Software
Input Resistance >10 MΩ (SE), >20 MΩ (DE)
Input Type Thermocouple, Voltage
Isolation 500V from PC
Length 182 mm
Number of Channels, Input Analog: 5 DE, 10 SE, Frquency/Pulse: 2, Digital: 8
Number of Channels, Output Digital: 8
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
Output Resistance 10 Ω
Output Signal Digital
Pull-up Resistor 27 KΩ to 5V for Switch or Relay Sensing
Relative Humidity 0 to 95% RH non-condensing
Sampling Rate 80 Hz (80 updates/second)
Software DASYLab®, and LabVIEW®
Supply Power Note Powered from USB, or from external 6 to 16 Vdc when used with a bus powered hub
Supply Power Type DC/USB
Supply Voltage 6 to 16 Vdc
Voltage Measurement Range ±20V, -10 to 20V, ±10V, ±5V, ±4V, ±2.5V, ±2V, ±1.25V, ±1V, ±625 mV, ±500 mV, ±312 mV, ±250 mV , ±156 mV , ±125 mV, ±62 mV, ±31 mV, Differential, Single ended
Width 92 mm
See All Specs Show Less
USB Data Acquisition Modules for Thermocouples Process Signals OMB-DAQ-55 OMB-DAQ-55
Rated 5 out of 5 by from ULTIMATE FOR RELIABILITY AND ACCURACY !!! RECOMMENDED FOR THERMOCOUPLE AND LOAD CELL MONITORING
Date published: 2017-12-24
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_OMB-DAQ-55, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
en-US
en
Save Configuration