  • Versatile device for liquid or gas supports designs requiring more precise measurements in support of application
  • Field selectable port swap eliminates costly re-plumbing if unit is re-installed or replaced
  • Uni-directional and bi-directional pressure selection with configurable output provides a single device that can meet broad application needs without having to specify multiple devices
  • Optional LCD display provides local status to identify operational conditions
  • NEMA 4 rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists
Series-WWDP
From $ 1,085.75
Wet-to-Wet Differential Pressure Transmitter, 30 Configurable Options Series-WWDP Series-WWDP
loading all models
Product Overview
  • Accuracy ± 1 %
  • Accuracy Note All pressure ranges have ± 1% FS accuracy except the lowest selectable range of each unit is ± 2% FS
  • Burst Pressure 10,000 psi Maximum
  • Compensated Temperature, Max 54 °C
  • Compensated Temperature, Min 0 °C
  • Compliance CE
  • Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
  • Electrical Output 4 to 20 mA, 0 to 5 Vdc, 0 to 1 Vdc
  • Enclosure Ratings IP56, NEMA Type 4
  • Long Term Stability ± 0.5%/year
  • Loop Resistance 1000 Ω
  • Media Compatibility Air, Alkaline solutions, Argon, Carbon dioxide, Dilute Acids, Helium, Hydraulic Oil, Hydrogen, Light Oil, Liquids, Nitrogen, Non-Corrosive Dry Gases, Oil, Oxygen, Solvents, Steam, Water, Water-based fluids
  • Output Detail Field selectable
  • Power Consumption max 40 mA
  • Pressure Type Differential
  • Process Connection Size 1/8 in
  • Process Connection Type NPT Female
  • Response Time 1 to 5 s
  • Response Time Note 1 to 5 s (selectable)
  • Span Adjustment Menu Option
  • Supply Power Type AC/DC
  • Supply Voltage 12 to 30 Vdc/18 to 28 Vac
  • Thermal Effects 2% FS/100°F
  • Thermal Effects Note 2% FS/100°F (50°C) includes zero and span
  • Weight 680.4 g
  • Zero Setting Adjustable Range Digital “re” zero button (should be used when changing ranges)

The Series WWDP Wet-to-Wet Differential Pressure Transmitter offers everything in one package by having 30 field selectable variations in just 3 models. The WWDP provides field selectable unidirectional and bidirectional pressure ranges, configurable 0-5, 1-5, 0-10 VDC, and 4 to 20 mA output. It also provides an auto-zero capability. The field selectable port swap feature eliminates costly replumbing if the unit is improperly installed or if the transmitter is simply replaced. An optional LCD display is available for on-sight indication of line and differential pressure. The all cast aluminum housing is rated NEMA 4 (IP66). These features make the WWDP transmitter an ideal instrument for measuring the flow of various liquids and gases, pressure drop across filters, measurement of liquid level or pressurized vessels, and for use in energy management and process control systems.

Calibration Option available under Accessories.

Product Applications

  • Monitor differential pressure of a chiller
  • Filter monitoring
  • Liquid level
  • Pressure vessels
  • Process control
  • Energy management
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 14ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration