Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

OM-CP-THERMALERT-Series

Wireless Temperature/Humidity Monitoring and Alarming System

Models In Stock
  • This product has been discontinued. Please see OM-CP-RFTEMP2000A for a potential replacement.
  • Precision RTD Sensing Element
  • View Data in Real-Time
  • 2 Year Battery Life
OM-CP-THERMALERT-Series
From $ 307.76
Models In Stock
Wireless Temperature/Humidity Monitoring and Alarming System OM-CP-THERMALERT-Series OM-CP-THERMALERT-Series
loading all models
Product Overview
  • Accuracy ± 1 min/month
  • Accuracy Detail Time: ±1 minute/month (at 25°C)
  • Calibration Digital calibrationthrough software
  • Calibration Accuracy Temperature: ±0.5°C; Calibration Accuracy: Temperature: ±0.5°C (±0.9°F) from 0 to 50°C (32 to 122°F)
  • Data Interface OM-CP-RFC1000-EXT
  • Data Interface Note OM-CP-RFC1000-EXT required; 115,200 baud
  • Display Type N/A
  • Electrical Connection N/A
  • Enclosure Material ABS Plastic
  • Height 5.25 in
  • Length 1.3 in
  • Memory 30,000 readings; software configurable memory wrap
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -20 °C
  • Probe Diameter 0 in
  • Probe Length 0 in
  • Process Temperature, Max 80 °C
  • Process Temperature, Min -20 °C
  • Reading Rate One reading every two seconds to one every 24 hours
  • Relative Humidity 0 to 95% RH non-condensing
  • Resolution Temperature: 0.01 °C
  • Sheath Material N/A
  • Software XP SP3/Vista/7 and 8 (32- and 64-bit)
  • Supply Power Note 3.6V lithium battery (included); user replaceable
  • Supply Power Type Battery
  • Temperature Probe Style N/A
  • Width 2.2 in
  • Wireless Receiver Sensitivity -95dBm typical

Description

The OM-CP-THERMALERTtemperature monitoring andalarming system is designedspecifically for hospitals,laboratories, pharmaceuticalfacilities and other criticaltemperature monitoring areas.The system can be used to monitora single temperature location orexpanded to include hundreds oflocations by adding additionaltransmitters.

The OM-CP-THERMALERT recordsboth ambient temperature andhumidity and provides real timenotification of temperaturedeviations, and features a userprogrammable alarm that can beconfigured to send a message viatext message, screen alarm/ore-mail if an alarm condition occurs.The system includes an internalsensor window.

The OM-CP-THERMALERT systemis equipped with wireless two-waycommunication. Full communicationcan be performed directly from acentral PC, including starting,stopping and downloading.In addition to wirelessly transmittingdata, it can also store each readingto internal memory for backup. Thisback up data may be retrievedwirelessly at a later time.Customers can setup automaticarchiving preferences, ensuring alldata is saved and retained tocomply with federal regulations.

Specifications
TEMPERATURE
Range:
-20 to 80 °C (-4 to 176 °F)
Resolution: 0.01 °C (0.018 °F)
Calibrated Accuracy: ±0.5 °C ( ±0.9 °F)0 to 50 °C
(32 to 122 °F)

WIRELESS
RF Frequency:
2.45 GHz IEEE802.15.4 ultra-low
power wirelesstransceiver with fully bi-directionalcommunication
Band: ISM band 2.405-2.48 GHz
Maximum Output Power: +0dBm typical
Receiver Sensitivity (OM-CP-RFC1000-EXT): -95dBm typical
Range:
  Outdoor Line-of-Sight 610 m (2000')
  Indoor: 152 m (500')

GENERAL
Reading Rate:
One reading everytwo seconds to one every 24 hours
Memory: 30,000 readings softwareconfigurable memory wrap
Wrap Around: Yes
Start Modes:
   Immediate start
   Delay start up to 18 months
Calibration: Digital calibration through software
Calibration Date: Automatically recorded within device
Battery Type: 3.6V lithium battery(included) user replaceable
Battery Life: 2 years typical
Data Format: Date and time stamped ºC, ºF, K, ºR
Time Accuracy: ±1 minute/month (at 25 °C)
Computer Interface: OM-CP-RFC1000-EXT required115,200 baud
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment:-20 to 80 ºC (-4 to 176 ºF),
0 to 95% RH non-condensing
Enclosure Material: ABS plastic
Dimensions: 133 L x 55 W x 33 mm D (5.25 x 2.2 x 1.3")
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 17ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
en-US
en
Save Configuration