OM-CP-RFVOLT2000A-Series

Wireless Voltage Data Logger with Display

Models In Stock
  • Wireless Two-Way Communications
  • 2.5V, 15V, 30V or 160 mV Measurement Ranges
  • 160 mV Model Measures Differential Voltage
  • Digital Display Provides Instant Access to Current Readings and Statistics
OM-CP-RFVOLT2000A-Series
From $ 375.00
Models In Stock
Wireless Voltage Data Logger with Display OM-CP-RFVOLT2000A-Series OM-CP-RFVOLT2000A-Series
loading all models
Product Overview
  • Alarm Note User configurable audible, on-screen, email and text (SMS) alarms, Alarm Delay: A cumulative alarm delay may be set in which the device will activate the alarm (via LED) only when the device has recorded a user specified time duration of data, Audible Alarm Functionality: 1 beep per second for reading alarm above/below threshold
  • Approvals CE, FCC, IC, KCC
  • Band Frequency 2.405 to 2.475 GHz
  • Band Frequency Note ISM band 2.405 to 2.475 GHz operation (channels 11 through 25) @ 250 kbps data rate
  • Battery life 3 yr, typical with reading interval of 15 min
  • Battery Size and Type Li-ion, 9V
  • Baud Rate 250000
  • Calibration Digital Calibration through Software
  • Calibration Date Automated
  • Configuration Omega Data Logging Software, Windows PC
  • Conversion Time 150 milliseconds
  • Data Interface Wireless, USB
  • Display LCD
  • Form factor Wall Mount
  • Height 0.95 in
  • Input Type External
  • LED Functionality Green LED blinks every 5 seconds to indicate unit is logging, Blue LED blinks every 15 seconds to indicate unit is in wireless mode, Red LED blinks every 1 second to indicate alarm condition
  • Length 3 in
  • Logging Modes Fixed interval
  • Materials Plastic
  • Measurement Type Voltage
  • Memory Modes Yes
  • Number of Measurements 1
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -20 °C
  • Overload Protection ± 50 Volts for 2 seconds
  • Relative Humidity 0 to 95% RH non-condensing
  • RF Frequency 2.45 GHz
  • RF Frequency Note 2.45GHz IEEE 802.15.4 ultra-low power wireless transceiver with fully bi-directional communication
  • Samples,Max 32256 Samples, Interval Selectable 1 Sec to 24 hrs
  • Sensor Type Voltage Sensor
  • Software XP SP3/Vista/7 and 8 (32 and 64-bit)
  • Start Modes Delayed Start, Immediate Start
  • Supply Power Note Ultralife 9V lithium battery included; user replaceable
  • Supply Power Type Battery
  • Time Accuracy ± 1 minute/month
  • Weight 4.1 oz
  • Width 3.5 in

Description

The OM-CP-RFVOLT2000A is a wireless data logger designed to measure and record DC voltage signals. The data logger can connect directly to DC voltage sources which makes it ideal for battery usage studies, solar energy monitoring and other DC voltage monitoring applications. The OM-CP-RFVOLT2000A can also be interfaced with a wide range of voltage output devices, including pressure transducers and other process sensors. The OM-CP-RFVOLT2000A is available in a 2.5V, 15V, 30V or 160 mV measurement range.

The OM-CP-RFVOLT2000A features an LCD screen which provides instant access to the current reading, minimum, maximum and average statistics. Through the software, the device can be programmed with engineering units, which convert the voltage signals into a different unit of measure such as PSI, % or PPM. The engineering unit is available for display on the LCD screen as well as in the software. The statistics can be reset through the keypad of the device, allowing customers to keep track of statistics over certain time periods. This feature does not erase the data recorded, but only resets the statistics count.

The OM-CP-RFVOLT2000A can be used as a standalone data logger, or used with the OM-CP-RFC1000-EXT wireless transceiver, to transmit data back to a central PC. The OM-CP-RFVOLT2000A transmits up to 152 m (500') line of sight to the OM-CP-RFC1000-EXT transceiver. Multiple OM-CP-RFC1000-EXT’s can be used as repeaters and transmit up to 305 m (1000') line of sight to other OM-CP-RFC1000-EXT’s. This allows the data to be sent over a greater distance.

The OM-CP-RFVOLT2000A-160MV model is a wireless, differential voltage data logger. The device is equipped with a three position terminal block to allow for a positive, negative and ground connection. This allows the measurement of the voltage difference between two signals tied to the same ground.

The OM-CP-RFVOLT2000A can be used as a single, wireless data logging system, or can be expanded to a large scale system, which can include hundreds of data loggers measuring different parameters such as temperature, humidity and more (additional wireless data loggers and transceivers may be required). Data can be viewed in graphical or tabular formats and summary and statistics views are available for further analysis. The software features export to Excel®, data annotation, digital calibration and more.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Where is the manual for the OM-CP-RFVOLT2000A ? Your manual choices doesn't cover it.

Asked by: Victor
Hi, we do apologize for not having the correct manual on the website, and will fix this. Our Tech Support has emailed you the manual you require. We also have a link for all manuals: https://www.omega.com/en-us/pdf-manuals
Answered by: Jane
Date published: 2019-05-21
  • y_2025, m_2, d_21, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_OM-CP-RFVOLT2000A-15V, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 32ms
  • QUESTIONS, PRODUCT
en-US
en
Save Configuration