DP41-RTD

Choose a Variant
Supply Voltage
Control Output
Output Configurations
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$1 454.38 |
5-9 | C$1 381.66 |
10-24 | C$1 308.94 |
25-49 | C$1 236.22 |
50-99 | C$1 163.50 |
100+ | C$1 090.79 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
A/D Conversion | Dual-slope technique |
Accuracy | ± 0.005 % |
Common Mode Rejection | 120 dB |
Common Mode Voltage | 1500 Vp per HV test |
Control Output | None |
Current Measurement Range | 0 to 20 mA, 4 to 20 mA |
Cutout Dimensions | 45 x 92 mm |
Data Interface | N/A |
Display Color | Red, Green |
Display Size | 13.7 mm (0.54 in) |
Display Type | 6 Digit Single LED |
Display Type Note | Red or green 6-digit, 14-segment, 13.7 mm (0.54") high; 4 alarm indicators |
Enclosure Ratings | IP65, NEMA Type 4 |
Form factor | 1/8 DIN |
Height | 48 mm |
Input Configuration | Single-ended |
Input Type | RTD indicator |
Input Type Note | RTD Input: Any 6 Ω to 6 kΩ NIST or DIN platinum and any linear RTD RTD Connection: 2-, 3- or 4-wire |
Length | 165 mm |
Normal Mode Rejection | 60 dB |
Number of Inputs | 1 |
Offset Adjustment | 0 to 999,999 or 0 to -99,999, programmable |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | 0 °C |
Output Configurations | None |
Output Configurations Note | None |
Output Detail | Isolated, tri-state, TTL/CMOS compatible; external 5V supply required for isolated; internal 5V supply for non-isolated |
Polarity | Unipolar/Bipolar, programmable |
Power Consumption | 10 W |
Power Consumption Note | 6 W nom., 10 W max |
Reading Rate | 3/s or 13/s, 60 Hz; 3/s or 12/s, 50 Hz |
Relative Humidity | 95% RH, non-condensing |
Resolution | 15-bit |
Sampling Rate | 13 Hz (13 updates/second) |
Sensor Break Protection | Up-scale or down-scale, programmable |
Sensor/Transmitter Power | 10 V at 30 mA; 24V at 25 mA |
Setpoint | 4 isolated open collector; rated 150 mA at 1V sink, 30V open |
Span Adjustment | 0.00001 to 500,000 counts, programmable |
Step Response | 1 sec to 99.9% |
Storage Temperature, Max | 85 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | 115 or 230 Vac, 49 to 400 Hz; 10 to 32 Vdc |
Supply Power Type | AC |
Supply Voltage | 115 to 230 Vac |
Temperature Measurement Range | RTD 1: -200 to 200°C,RTD 2: -200 to 900°C,RTD 3: -200 to 850°C |
Thermal Span Effect | ±20 ppm |
Voltage Measurement Range | 33 to 100 mV, 0 to 1V, 0 to 5V, 1 to 5V, 0 to 10V, 0 to 100V, ±50 mV, ±500 mV, ±5V, ±50V |
Warm-Up to Rated Accuracy | 50 min |
Weight | 574 g |
Width | 96 mm |
See All Specs |
Show Ratings & Reviews
Rated 1 out of
5
by
15YearsOfExperiance from
Garbage
The scaling is a "unique" process, wherein a simple zero point and span point will not be sufficient, and a scaling and offset coefficient will need to be altered for correct span value and zero/null reading respectively. This isn't inline with industry standards. Where most other instrument manufactures have implemented such a basic function as two point linearity, the DP-41 requires extra steps. It has a two point linearity feature, however it simply doesn't work. After designating a zero and span value, and returning to operation mode, the applied values from adjustment will not match the meter display. This was confirmed in calibration lab on a calibrated bench meter (34401A) and a power supply (6115A).
What's more, if the 2 point scaling procedure is done multiple times, the parameters will change by a large margin (we saw about a 350% error between scaling procedures, performing the operation 20 times). This isn't random; the error occurs every other time. Again, two point scaling is a very basic function of most instrumentation that the DP-41 fails at accomplishing.