Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

LC202-5K

5,000 lbf, ± 0.25%, Linearity, 2 mV/V Output, Cable

C$1,366.30

Item# LC202-5K

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 C$1,366.30
10-24 C$1,297.99
25-49 C$1,270.66
50-99 C$1,216.01
100+ C$1,188.68

In Stock

Lead Time (If not in stock): 4 weeks

Product Specs

<< See all Product Models
Brand
5-Point Calibration 0%, 50%, 100%, 50%, 0%
Accuracy ± 0.25 %
Cable Length 5 ft
Calibration Option 5 POINT NIST
Electrical Connection Cable
Electrical Output 2 mV/V
Enclosure Ratings IP65
Force Type Compression, Tension
Height 2.23 in
Hysteresis ± 0.25%
Input Resistance 360 Ω min
Linearity ± 0.25%
Load Cell Capacity 5000 lbF
Load Cell Type In-line
Materials Stainless Steel
Operating Temperature, Max 121 °C
Operating Temperature, Min -54 °C
Outer Diameter 1.25 in
Output Resistance 350 ± 10 Ω
Overload, Max 300% FS
Process Temperature, Max 71 °C
Process Temperature, Min 16 °C
Repeatability ± 0.25%
Safe Overload 150% FS
Supply Power Note 10 Vdc, 15 Vdc maximum
Supply Voltage 10 Vdc
Thermal Span Effect 0.009% FSO/°C
Thermal Zero Effect 0.009% FSO/°C
Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
Zero/Balance Error ± 2%
See All Specs Show Less
5,000 lbf, ± 0.25%, Linearity, 2 mV/V Output, Cable LC202-5K LC202-5K
Rated 5 out of 5 by from reliable data The unit is functioning well and producing good data on tension. I'm happy with the purchase.
Date published: 2016-11-14
Rated 5 out of 5 by from Cable Cable works as expected. Pricing was good. Delivery was timely.
Date published: 2024-01-23
Rated 3 out of 5 by from The Omega 2000 lbf load cell is too tiny. We never used the Omega 2000 lbf load cell. It looked too small to hold-up to 2000 lbf with the gorillas that work on our system. We went with a more robust larger load cell instead that could stand more unintentional abuse. The typical load is ~ 700 lbf, however, someone could overload it by accident. If the load cell failed and the load dropped, I would never hear the end of it.
Date published: 2023-08-14
Rated 5 out of 5 by from Easy Setup It was easily set up with the DPS20-LV and initial testing seems to have went well.
Date published: 2023-03-06
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_LC202-5K, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
en-CA
en_CA
Save Configuration