Welcome to our new website, found an issue or bug? Please report it here

BB705-series
100 °C to 1046 °C Temperature Blackbody Calibrator
- Very High Temperature Blackbody Calibrator
- Model BB705 Calibrates from 100 to 1046°C (212 to 1915°F)
- Built-In NIST Traceable Reference Temperature Display
- Large 44.5 mm (1.75') Aperture
BB705-series
From
C$
25 124.15

Product Overview
- Accuracy ± 1 °C (± 1.8 °F)
- Accuracy Note ±0.25% of reading; ±1°C
- Additional Features 1 Portable
- Cavity Emissivity 0.99
- Cavity Opening Size 44.5
- Control Mode PID Control
- Data Interface RS232
- Display Type LED
- Frequency 50/60 Hz
- Height 520 mm
- Internal Sensing Element Platinum Thermocouple
- Length 600 mm
- Operating Temperature, Max 35 °C
- Operating Temperature, Min 0 °C
- Process Temperature, Max 1046 °C
- Process Temperature, Min 100 °C
- Stability ± 0.4°C
- Stability Note 0.4°C (0.7°F) per 8-hour period
- Target Size 44.5
- Warm Up Time 80 min
- Warm-Up Time Note 80 minutes from 100°C to 1000°C
- Width 566 mm
This BB705 is a blackbody temperature reference source which is adjustable over the range from 100 to 1046°C (212 to 1915°F) and accurate to ±1°C, ±0.25% rdg. It has a built-in digital temperature controller to provide accurate, stable temperatures as well as to provide the temperature readings of the cavity. The heated cavity provides a target of known temperature and emissivity, and virtually any infrared pyrometer with a spot size diameter less than 44.5 mm (0.88") can be calibrated. Calibration setups are easy with the BB705. An independent NIST traceable probe and high accuracy panel meter provide temperature reference information. Both models come standard with an RS-232 computer interface which allows computer control of the setpoints for automatic test applications. A NIST traceable calibration certificate is also provided.
PLEASE NOTE: Items listed as "Stock" require 5 Business Days for NIST Certification and Order Processing
PLEASE NOTE: Items listed as "Stock" require 5 Business Days for NIST Certification and Order Processing
PDFs & Manuals
Show Ratings & Reviews
I have a question about the Blackbody Calibrator for Very High Temperature Infrared Calibration (Item# BB705). Can it be used for calibrating heat flux sensors?
Thank you for your interest in our product
.
Please provide more details of your Heat Flux Sensor and email to temperature@omega.com for further review.
The factory does not use Blackbody Calibrators for Heat Flux Sensor calibration
A guarded hot plate and a conduction /reference sensor system is used
Date published: 2025-01-07