Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

CL945A

Industrial Thermocouple Handheld Calibrator

C$2,684.51

Item# CL945A

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 C$2,684.51
5-9 C$2,550.28
10-24 C$2,496.59
25-49 C$2,389.21
50-99 C$2,335.52
100+ C$2,281.83

In Stock

Lead Time (If not in stock): 9 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 Read and Source Signals
Auto Off 20 min
Auto Off Note 20 minute no key pressed Auto Off. Feature can be disabled
Battery Indication 4 stage battery charge indication
Battery life 500 hr
Cold Junction Error ± 0.15 °C
Common Mode Voltage 42 V
Common Mode Voltage (CJC error), Max 1 V
Common Mode Voltage Note 42 V peak to earth; 1 V p-p between T1 and T2
Compliance CE, Mil-PRF-28800F Class 2, REACH, RoHS 2
Dimensions (CJC error) 7.6 L x 3.3 W x 1.1 H in
Display Backlight Four (4) LED Backlight with 30-second timeout
Display Measuring Units °C, °F, mV
Display Resolution 0.01°
Display Resolution (CJC error) 0.1°
Display Type Backlit LCD
Display Type Note 5-DIGIT AUTO-RESOLUTION (0.1/0.01) WITH BACKLIGHT AND FUNCTION ANNUNCIATORS Two (2) rows of Five (5) digit LCD with separate minus sign, decimal indicators, with offset, thermocouple types KJTEBNRSGCDPLU, battery, source, read, temperature units, voltage units, percent, trend, PRST (0-19), MIN, MAX, AVG, RNG, STDEV, Transfer, symbols: Fast Ramp, Slow Ramp, Step, Bluetooth
EMC Standard Class 2, EN 61326, MIL-PRF-28800F
ESD Standard IEC 61326 Criterion B
Electrical Connection Miniature Female Thermocouple Connector
Electrical Safety IEC-61010
Height 28 mm
Input Current ± 50 nA
Internal Preset Storage 20 user defined presets available
Keypad 12 Switches
Length 193 mm
Low Resistance Load Less than 5µV change in output with a 100KΩ resistance
Millivolt Range -15 to 85 mV
Operating Environment Altitude: 0 to 4600 m ; 0 to 15,092 ft(CJC Error) Vibration: Random 10 – 500 Hz; 0.03 g2/Hz(CJC Error) Shock: 30g Half Sine Drop: 4 Drops from 1 m to Concrete
Operating Temperature Note Operating Temperature(CJC error): -4 to 131°F
Operating Temperature, Max 55 °C
Operating Temperature, Min -20 °C
Power Cycle Configuration Retention Instrument retains: Sensor Type, Temperature Unit Offset Values, Presets, Statistics, Open Lead detection status, 0%/100% span settings, and operating mode
Probe Offset Uncertainty Resolution 0.1 °C/°F
Reading Rate 3/sec
Reading Rate Note 3/sec. for Readings and TREND indicators
Relative Humidity Note <10 °C (50 °F): Non-condensing 10 to 30 °C (50 to 86 °F): 5 to 95% RH 30 to 40 °C (86 to 104 °F): 5 to 85% RH 40°C to 55°C (104 to 131 °F): 5 to 60% RH
Relative Humidity, Max 0.95
Relative Humidity, Min 5%
Resolution Note 0.01°C UP TO 999.99°C AND 0.1°C ≥ 1000°C
Resolution, Max 999.99 °C
Resolution, Min 0.01 °C
Sanitation NSF, ANSI/3-1 14159-2
Statistics Average, Maximum, Minimum, Range, Standard Deviation
Storage Temperature Note Storage Temperature(CJC error): -59.8 to 159.8°F
Storage Temperature, Max 71 °C
Storage Temperature, Min -51 °C
Supply Voltage 4.5 Vdc
Temperature Coefficient For specification variances due to ambient operating temperature, see the Expanded Instrument Uncertainty charts in Appendix B of this manual. For ambient operating temperatures not shown in Appendix B, accuracies shall be interpolated linearly.
Thermocouple Type J, K, T, E, R, S, B, C, N, L, G, U, D, P
Weight 362.9 g
Weight (CJC error) 12.8 oz (including batteries)
Weight Note 362.9g (including batteries)
Width 84 mm
See All Specs Show Less
Industrial Thermocouple Handheld Calibrator CL945A CL945A
Rated 5 out of 5 by from great product, needs accessories great use for our purpose, If they have included male to male extension for the TC calibration it would have been great.
Date published: 2024-04-29
Rated 4 out of 5 by from Works as we need it to. A bit too expensive Tool works great. Meets our needs although requires a capacitor the older model didn’t to calibrate multiple zones at once.
Date published: 2023-05-08
Rated 5 out of 5 by from Director Very reliable and trustable , have been working with Omega for two decades
Date published: 2023-04-11
Rated 4 out of 5 by from CL 940 review Excellent unit, but wish it had a rubberized protective grip case like our CL25 does
Date published: 2020-09-28
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_CL945A, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
en-CA
en_CA
Save Configuration