Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy Note | ± 1% of the measured value or 3°C whichever value is greater (The sensor head must be at constant ambient temperature for a minimum of 15 minutes) |
Cable Length | 3 m |
Control Output | Relay Output with hysteresis 60V DC/42V AC RMS,0.4A |
Data Interface | USB |
Display | Yes |
Electrical Output | 0 to 20 mA, 4 to 20 mA, 0 to 10 Vdc |
Emissivity, Max | 1.2 |
Emissivity, Min | 0.1 |
Enclosure Ratings | IP65 |
Field of view | 15:1 |
Housing Height | 33 mm |
Housing Length | 112.5 mm |
Housing Material | Stainless Steel,Zinc |
Housing Width | 82.5 mm |
Intrisically Safe | No |
Isolation | Power supply, *Digital output and Analog output are galvanically isolated * Not applicable for USB 2.0 digital output |
Laser Output | false |
Laser Power | None |
Operating Temperature, Max | 120 °C |
Operating Temperature, Min | 0 °C |
Output Detail | 0 to 20mA, 4 to 20mA, 0 to 10V, Thermocouple Type “K” or “J”, Relay Output with hysteresis 60V DC/42V AC RMS,0.4A |
Output Signal | Current, Voltage |
Photodetector Type | Thermopile |
Power Consumption | 2.5 W |
Process Temperature, Max | 800 °C |
Process Temperature, Min | 0 °C |
Relative Humidity, Max | 0.95 |
Relative Humidity, Min | 10% |
Relay Output | 60 Vdc |
Relay Output Note | Relay Output with hysteresis 60V DC/42V AC |
Repeatability | 0.003 |
Repeatability Note | 0.3% of reading + 1°C |
Response Time | 20 ms |
Response Time Note | 20 msec adjustable up to 10 sec |
Sighting Option | None |
Spectral Response, Max | 14 μm |
Spectral Response, Min | 8 μm |
Storage Temperature, Max | 70 °C |
Storage Temperature, Min | -20 °C |
Supply Power Note | 12V to 28V DC with reverse polarity protection |
Supply Voltage | 12 to 28 Vdc |
Temperature Coefficient | ± 0.06% |
Temperature Coefficient Note | ± 0.06 °C/°C (0.06 °F/°F) or ± 0.06 % (whichever is greater) |
Weight | 600 g |
See All Specs |
PDFs & Manuals
Software & Drivers
Calibration
Show Ratings & Reviews
Rated 5 out of
5
by
Shweta Jaroli from
Great Performance
We are satisfied with performance of this pyrometer.
Date published: 2021-09-02
Rated 1 out of
5
by
SSmith from
Does Not Work
The display frequently freezes at a temperature and stops live updating. The power wires going into the device are exposed because the wrapping is too short. They will likely break from moving the device or rip out. The OmegaSoft data collection software will either record to an old file or say that it can't record because a file is active. The "Start" and "Stop" data collection functions do not work.
Date published: 2021-03-26