Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

We noticed you are from . Visit your local site for regional offers and live support.

DPG9000

Advanced Digital Pressure Gauge with Output and Alarms

Models In Stock
  • A Multi-Functional Digital Gauge with Optional 4 to 20 mA Output and (1) or (2) SPDT Switches
  • ± 0.25% of Span Terminal Point Accuracy
  • IP65 (NEMA 4) Weatherproof Case
  • 3' Stainless Steel Case or 4 1/2' Fiberglass Reinforced Thermoplastic Case
DPG9000
From C$ 931.68
Models In Stock
Advanced Digital Pressure Gauge with Output and Alarms DPG9000 DPG9000
loading all models
Product Overview
  • Accuracy Class 0.1% to 0.25%
  • Accuracy Detail 0.25% Full Scale, terminal point
  • Battery life 1000 hr
  • Connection Location Lower, Left, Right, Upper
  • Display Type LCD
  • Display Type Note Type: LCD Display Digits: Five (5) Character Height: 3˝ .60˝, 41 ⁄2˝ .88˝ Backlite: Optional Bar Graph: Yes Battery Life: 3˝ >1000 hrs., 41 ⁄2˝ >3600 hrs. Agency Approvals: CE, FM* (Intrinsically Safe Class1, Div 1), CSA and CENELEC *FM is not available with the following: 41 ⁄2˝ polypropylene case, SPDT switch option(s) (XU1, U2) or Backlite (XBL) option).
  • Keypad Functions On/Off: Manually turns unit on and off (auto off options in menu) Zero/Clear: Zeros display or clears min. and max. values when displayed Min/Max (down) Stores min and max values, arrow key allows for Arrow Key: scrolling thru menu items. Menu Key: Provides access to menu options. Backlite Arrow Key: Manually turns backlite on and off (auto off options in Arrow Key: menu), arrow key allows for five menu options. (up)arrow key allows for scrolling thru menu options. Enter: Selects items in the menu.
  • Menu Mode Engineering Units: 10 units of measurement are available; psi, In. H2O (with three temp. options: 20°C, 60°F, 4°C*), Ft. H2O, mPa, mBar, kPa, kg/cm2 , Bar, inHg and mmHg. Configuration Mode: Allows for changes to default settings of gauge Allows for changes to default settings of gauge. Bar Graph: Allows for adjustment of bargraph and 4-20 (optional feature). Auto Off (Off): Allows for changes to auto off of gauge, five options: Never, 2 min., 5 min., 15 min., 30 min. Update Rate: Four options: 100 ms, 200 ms, 500 ms, 1 sec Dampening: Six options: None, average, 2, 4, 6, 8 times per 100ms. Backlite: Five options: Never, 10 sec., 30 sec., 1 min., 5 min. Field Recalibration:Allows for recalibration of zero, midscale and span (password protected)
  • Number of Digits 5
  • Operating Temperature, Max 140 °F
  • Operating Temperature, Min 14 °F
  • Pressure Accuracy ± 0.25 %
  • Process Connection Size 1/4 in
  • Process Connection Type NPT Male
  • Storage Temperature, Max 158 °F
  • Storage Temperature, Min -4 °F
  • Supply Power Note 12-36 Vdc, 2VA maxBattery Note:
  • Supply Voltage 12 to 36 Vdc
SPECIFICATIONS
Accuracy: ± 0.25% of span, terminal point (0.13% BFSL)
Case Size: 76 mm (3'), 114 mm (4.5')
Case Material: 3' stainless steel, 4.5' fiberglass-reinforced thermoplastic
Case Encl. Rating: Weatherproof, NEMA 4 (IP65)
Wetted Materials: 17-4 SS (sensor), 316 SS (socket)
Socket Size: ¼ NPT Standard; Custom: ½ NPT, JIS, DIN, SAE, (½ NPT only with 4.5' case, others on application). Consult Engineering to order custom socket.
Socket Connection: Lower (standard); 3, 9 and 12 o'clock optional
Operating Temp: 10 to 60°C (14 to 140°F)
Temp Error: (Zero and span) 0.08%/°C (0.04%/°F) (<0.04%°C typical)
Storage Temp: -20 to 70°C (-4 to 158°F)
Display: 5-digit LCD
Character Height:
3' Case: 15 mm (0.60')
4.5' Case: 22 mm (0.88')
Backlight: Standard
Bar Graph: Standard
Battery Life: 3' >1000 hr, 4.5' > 3600 hr
Power Options:
DC Power: 12 to 36 Vdc, 2 VA max
Loop Power: 12 to 36 Vdc
Electrical Rating on Optional Switch (Option S1 or S2 DPG9200 series only): (1) or (2) SPDT switches; 30 Vdc 1 A max, 125 Vac 5 A (switches adjustable to 100% of range)
Backlit Display: Models 9x30 and 9x45
Battery Back-Up: Models 9130, 9230, 9145, 9245

KEYPAD FUNCTIONS:
On/Off: Manually turns unit on and off (auto-off options in menu)
Zero/Clear: Zeros display or clears min and max values when displayed
Min/Max (Down) Arrow Key: Stores min and max values, arrow key allows for scrolling menu items
Menu Key: Provides access to menu options
Backlit (Up) Arrow Key: Manually turns backlite on and off (auto-off options in menu); arrow key allows for 5 menu options. (Up) arrow key allows for scrolling menu options.
Enter: Selects items in the menu

MENU MODE:
Engineering Units: 10 units of measurement are available: psi, inH2O (with three temp options: 20°C, 60°F, 4°C), ftH2O, mPa, mbar, kPa, kg/cm2, bar, inHg and mmHg
Configuration Mode: (Config) Allows for changes to default settings of gauge, including zero disable feature
Bar Graph: (Graph) Allows for adjustment of bar graph and 4 to 20 mA (optional feature)
Auto Off (5 Options): (Off) allows for changes to auto-off of gauge: never, 2 min, 5 min, 15 min, 30 min
Update Rate (4 Options): (Update) 100 ms, 200 ms, 500 ms, 1 s
Dampening (6 Options): (Damp) None, average, 2, 4, 6, 8 times per 100 ms
Backlite (5 Options): Never, 10 s, 30 s, 1 min, 5 min
Field Recalibration: Allows for recalibration of zero, midscale and span (password protected)

Examples of pricing for popular models with backlit display are referenced
in the 'To Order' box.