Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 1 % |
Accuracy Note | ± 1% of reading (between 10% and 100% of maximum flow) ± 3% of reading (between cutoff and 10% of maximum flow) |
Battery Size and Type | Alkaline AA |
Cable Length | 20 ft |
Conductivity | > 20 µS/cm |
Display Type | LCD |
Electrical Connection | M12 5 pin Male |
Empty Pipe Detection | Hardware/software, conductivity-based |
Enclosure Ratings | NEMA Type 4X |
Materials | Aluminum, Polyethylene |
Materials, Wetted | 316 Stainless Steel, Glass, Polypropylene |
Media Compatibility | Acid Solutions, Conductive Liquids, Saltwater |
Number of Digits | 8 |
Number of Outputs | 1 |
Operating Pressure, Max | 150 psi |
Operating Temperature, Max | 54 °C |
Operating Temperature, Min | -12 °C |
Output Detail | Current sinking pulse, Opto-isolated, 32 Vdc maximum at 10 mA maximum |
Output Signal | DC Pulse |
Pipe Size, Max | 1 in |
Pipe Size, Min | 1 in |
Process Connection Note | 1 NPTF, 2 or 3" flange clamps with 2 or 3 NPTF fitting kit |
Process Connection Size | 1 in |
Process Connection Type | NPT Female |
Standard Pulse Rate | 1 unit/pulse out |
Standard Pulse Rate Note | 1 unit/pulse out, Pulse width of 10 ms depending on unit selection |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | FMG800: 6 each “AA” alkaline cells (included), replaceable. Estimated life is 1 to 2 years depending on usage, FMG810: 10 to 30 Vdc @ 60 mA maximum (15 mA average), NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation. |
Supply Power Type | DC |
Supply Voltage | 10 to 30 Vdc |
Volumetric Flow Rate, Max | 110 GPM |
Volumetric Flow Rate, Min | 2.3 GPM |
Weight | 0 lb |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
85westymmm from
FMG810 does NOT have pulse output
I believe the model numbers (FMG800 and FMG810) are reversed in the description as to which one provides a pulse output. I believe the FMG800 requires a permanent power supply (non-battery operated) but provides a pulse output signal. The battery-operated FMG810 does NOT provide a pulse output.