Welcome to our new website, found an issue or bug? Please report it here

TQ601
Combination, Torque and Thrust Sensors with Separate Outputs
- Separate Outputs for Torque and Thrust
- All Stainless Steel for Long Term Reliability in Industrial Environments
- IP65 Protection
- High Accuracy
TQ601
From
C$
3 783.17

Product Overview
SPECIFICATIONS
TORQUE CELL
Output: 2.0 mV/V
Excitation: 10 Vdc, 15 V max
Input Resistance: 360 Ω min.
Output Resistance: 350 ±5 Ω
Linearity: ±0.2% FSO
Hysteresis: ±0.10% FSO
Repeatability: ±0.05% FSO
Thermal Effects:
Zero: ±0.005% FSO/°F
Span: ±0.005% Rdg/°F
Safe Overload: 150% of Capacity
Ultimate Overload: 300% of Capacity
THRUST CELL
Output: 2.0 mV/V
Excitation: 10 Vac/dc, 15 V max
Input Resistance: 360 Ω min.
Output Resistance: 350 ±5 Ω
Linearity: ±0.15% FSO
Hysteresis: ±0.10% FSO
Repeatability: ±0.05% FSO
Zero Balance: ±2% FSO
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.005% Rdg/°F
Safe Overload: 200% of Capacity
Ultimate Overload: 300% of Capacity
COMMON SPECIFICATIONS
Operating Temperature: -46 to 107°C (-50 to 225°F)
Compensated Temperature: 16 to 71°C (60 to 160°F)
Construction: Stainless Steel
Electrical: Two (2) 10 ft (3 m) 4-conductor shielded PVC Cables
PLEASE NOTE THAT THIS IS A 'BUILT TO ORDER' PRODUCT AND IS NOT TYPCIALLY STOCKED.
PLEASE CONTACT OUR ENGINEERING DEPARTMENT TO DISCUSS DELIVERY NEEDS.
TORQUE CELL
Output: 2.0 mV/V
Excitation: 10 Vdc, 15 V max
Input Resistance: 360 Ω min.
Output Resistance: 350 ±5 Ω
Linearity: ±0.2% FSO
Hysteresis: ±0.10% FSO
Repeatability: ±0.05% FSO
Thermal Effects:
Zero: ±0.005% FSO/°F
Span: ±0.005% Rdg/°F
Safe Overload: 150% of Capacity
Ultimate Overload: 300% of Capacity
THRUST CELL
Output: 2.0 mV/V
Excitation: 10 Vac/dc, 15 V max
Input Resistance: 360 Ω min.
Output Resistance: 350 ±5 Ω
Linearity: ±0.15% FSO
Hysteresis: ±0.10% FSO
Repeatability: ±0.05% FSO
Zero Balance: ±2% FSO
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.005% Rdg/°F
Safe Overload: 200% of Capacity
Ultimate Overload: 300% of Capacity
COMMON SPECIFICATIONS
Operating Temperature: -46 to 107°C (-50 to 225°F)
Compensated Temperature: 16 to 71°C (60 to 160°F)
Construction: Stainless Steel
Electrical: Two (2) 10 ft (3 m) 4-conductor shielded PVC Cables
PLEASE NOTE THAT THIS IS A 'BUILT TO ORDER' PRODUCT AND IS NOT TYPCIALLY STOCKED.
PLEASE CONTACT OUR ENGINEERING DEPARTMENT TO DISCUSS DELIVERY NEEDS.
Show Ratings & Reviews
If the bottom plate of the torque cell is damaged, will this effect any readings? I currently have a version of this equipment.
If it's just the plate that's damage it still should be OK. I the internal circuitry was compromised it would effect the operation.
Date published: 2020-09-24