Product Specs
<< See all Product ModelsBrand |
![]() |
Leakage Current | < 50 µA |
Materials, Wetted | 316L Stainless Steel |
Media Compatibility | Oil, Solvents, Water |
Operating Pressure, Max | 250 psi |
Operating Temperature, Max | 80 °C |
Operating Temperature, Min | -29 °C |
Process Connection Size | 1/4 in |
Process Connection Type | NPT Male |
Protection | Transient, reverse polarity |
Repeatability | 2 mm |
Supply Power Type | DC |
Supply Voltage | 5 to 30 Vdc |
Switch Operation | Normaly Open |
Switch Rating | 1 A @ 60 or 120 Vac/Vdc |
Switch Type | SPST |
Time Delay | 0.5 sec |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
Cable User from
Missing document info
I couldn't find any documentation that describes the cable/wire information (gauge, insulation/jacket type, etc), so I wrote this review to provide that:
The cable that was attached to mine is a Belden 9535, and Belden provides a nice spec sheet on their website.
Date published: 2017-06-02
Rated 5 out of
5
by
James1 from
Great Sensor - Would Like to See Future Variations
Sensor operating voltage is versatile
(5-30VDC). My application uses 6VDC.
Sensor is compact enough to make it work in tight areas. It is 1/2” NPT and 3” long.
I would love to see the following variations in the future:
1) Make the wiring via a connector instead of cable coming out connector. This will allow easy removal.
2) If point 1 is not possible, make the cable longer, maybe 6-ft.
3) Make another sensor with longer length; may be 2-in longer. This will allow the shorter one to be used for level control, while the longer used for low level alarm.
Date published: 2021-03-11