Welcome to our new website, found an issue or bug? Please report it here

FMC-5000-Series
Coriolis Mass Flow Meter
Models In Stock
- Mass Flow Rate, Volume, Density and Temperature Measurements
- Rugged Meters with No Moving Parts Results in Minimal Maintenance
- Accuracy Over a Wide Flow Range From a Single Meter Optimizes Plant Efficiency
- No Flow Conditioning or Straight Pipe Runs Required, Making Installation Simplified and Less Expensive
FMC-5000-Series
From
C$
8,118.00
Models In Stock

Product Overview
- Additional Features 1 Remote Mounted Display/Transmitter
- Compliance CE, RoHS 2
- Data Interface RS485
- Data Interface Note RS485 (RTU Modbus®), HART® (-HART option)
- Density Accuracy ± 0.002 g/cm³
- Density, Max 3 g/cm³
- Density, Min 0.2 g/cm³
- Density Repeatability ± 0.001 g/cm³
- Electrical Connection 1/2 in NPT female Conduit with Screw Terminal block
- Electrical Output 4 to 20 mA, 0 to 10 kHz
- Enclosure Ratings IP65, NEMA Type 4X
- Humidity Range 5 to 95% RH
- Materials, Wetted 304 Stainless Steel, 316L Stainless Steel
- Operating Pressure, Max 230 psi
- Operating Pressure, Min 0 psi
- Operating Pressure Note 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]
- Operating Temperature, Max 55 °C
- Operating Temperature, Min -40 °C
- Output Detail Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale Current Output: 4 to 20 mA, 0.005% Full Scale
- Output Signal Current, DC Pulse
- Process Temperature, Min -50 °C
- Supply Power Note 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W
- Supply Voltage 18 to 36 Vdc
- Temperature Accuracy ± 1 °C
- Weight 26.5 lb
The FMC-5000 Coriolis Mass Flow Meter is designed according to the Coriolis Force Principle. It is widely used for flow measurements and custody transfer in many industries such as petroleum, petrochemical, chemical, pharmaceutical, pulp and paper, food and dairy, and more. As an advanced flow and density measurement instrument, it is widely used in the measurement of liquids, gases and slurries, and garners a high reputation among customers around the globe. Coriolis meters are typically used in applications like batch control, blending, filling, dosing, custody transfer, process gas measurements, and more.
The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation.
Specifications
Flow Range: See charts below
Connection: ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges
Maximum Pressure: 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]
Body Material: 304 Stainless Steel
Measuring Tube Material: 316 L SS
Process Temperature Range:
Integrate Type: -50 to 125°C (-58 to 257°F)
Remote Type (-R): -50 to 200°C (-58 to 392°F)
Ambient Temperature: -40 to 55°C (-40 to 131°F)
Working Humidity: (5 to 95%) RH at 25°C (77°F)
Flow Accuracy/Repeatability:
FMC-5100: 0.1/0.05% (Liquid Only)
FMC-5200: 0.2/0.1% (Liquid Only)
FMC-5500: 0.5/0.25%
Density Measuring:
Range: 0.2 to 3.0 g/cm3
Error: ± 0.002 g/cm3
Repeatability: 0.001 g/cm3
Temperature Accuracy: ± 1.0°C
Protection: NEMA 4X (IP65)
Approvals: CE, RoHS
Communications: RS485 (RTU Modbus®), HART® (-HART option)
Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale
Current Output: 4 to 20 mA, 0.005% Full Scale
Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W
The FMC-5000 Series Coriolis Meter is designed according to the principle of Coriolis force. Under the alternating current effect, the electromagnetic coils mounted on the measuring tube will make two parallel measuring tubes vibrating at a certain fixed frequency. Whenever mass (either liquid or gas) flows through the measuring tubes, Coriolis force is generated, causing a “bending” or “deflection” in the top of the tubes. This deflection is sensed as a phase shift between two electronic pick-ups mounted on the tubes. The degree of phase shift is directly proportional to the mass flow within the tubes. The mass flow rate can be calculated by detecting the phase shift of the tubes. The temperature is also measured and used for compensation.
Specifications
Flow Range: See charts below
Connection: ANSI, DIN, JIS, or Sanitary Tri-Clamp flanges
Maximum Pressure: 16 bar (230 psi), [Optional: 25 bar (360 psi), 40 bar (580 psi) and 63 bar (913.7 psi)]
Body Material: 304 Stainless Steel
Measuring Tube Material: 316 L SS
Process Temperature Range:
Integrate Type: -50 to 125°C (-58 to 257°F)
Remote Type (-R): -50 to 200°C (-58 to 392°F)
Ambient Temperature: -40 to 55°C (-40 to 131°F)
Working Humidity: (5 to 95%) RH at 25°C (77°F)
Flow Accuracy/Repeatability:
FMC-5100: 0.1/0.05% (Liquid Only)
FMC-5200: 0.2/0.1% (Liquid Only)
FMC-5500: 0.5/0.25%
Density Measuring:
Range: 0.2 to 3.0 g/cm3
Error: ± 0.002 g/cm3
Repeatability: 0.001 g/cm3
Temperature Accuracy: ± 1.0°C
Protection: NEMA 4X (IP65)
Approvals: CE, RoHS
Communications: RS485 (RTU Modbus®), HART® (-HART option)
Pulse Output: 0 to 10 kHz, ± 0.075% Full Scale
Current Output: 4 to 20 mA, 0.005% Full Scale
Power Supply: 18 to 36 Vdc, 85 to 265 Vac (-AC option), 15 W
PDFs & Manuals
Show Ratings & Reviews
If i will buy this product, Can I get CO CQ of its??
Please contact us at PRESSURE@OMEGA.COM
For more details about this request
Date published: 2020-04-08
What process controller should I use to interpret the signal from the FMC-5201LA to display liquid density and send a 4-20 mA output to an exterior device?
Thank you for your inquiry! Something like our platinum series devices could be used to fulfill the needs of this application. Please contact us at flow@omega.com so that we can better tailor the instrument to your process.
Date published: 2021-08-12
I see that this meter can measure liquids with a little air in them, is that true in the case of other gases? ie. A majority of liquid CO2 with some CO2 bubbles? If not, could you recommend a high accuracy meter that could?
Thank you for your inquiry with the Coriolis flow meter. It is ideal that the media being measure is a single phase, not a mixture and it can affect the accuracy when measuring. All of Omega's flow products are calibrated to measure single phase medias.
Date published: 2022-09-19
If we were to use this as a totalizer for batches, is there any built-in totalizing option? or would this have to be done in a plc? and if so, im assuming the pulse output would be something specific like "1 litre per pulse" ? is it adjustable? Thank you
Thank you for your inquiry about this flow meter. Yes, it has a totalizer function and can be reset per batch if you wish.
Date published: 2023-02-27
what is the minimum to maximum size availability of coriolis flow meter ?
Pipe sizes are: 1/2, 1, 1 1/2, 2, 3, 4, and 6 inches.
Date published: 2020-03-09