1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

TFD-RTD
Surface Mount RTD with Brass Housing
Models In Stock
- Used in Wind Tunnels and Air Conditioners.
- Rapid Response Time
- Temperature Range: -50 to 550°C (-60 to 1020°F)
TFD-RTD
From
C$
57.94
Models In Stock

Product Overview
- Destruction Voltage 100 Vdc
- Electrical Connection Stripped Leads
- Hysterisis Error, Max 0.25
- Insulation Resistance >10⁸ Ω
- Insulation Resistance Note >10⁸ Ω @ 500°C
- Process Temperature, Max 500 °C
- Process Temperature, Min -70 °C
- Response Time, Air 13.5 sec @ 50%; 55 Sec @ 90%
- Response Time Note In Water Moving at 0.4 m/s: t(50%) = 0.25 s t(90%) = 1.1 s In Air Moving at 1 m/s t(50%) = 13.5 s t(90%) = 55 s
- Response Time, Water 0.25 sec @ 50%; 1.1 sec @ 90%
- Self Heating Effect 1.9 mW/°C
- Sensing Element Note TFD-design glass encapsulated Platinum layer on a ceramic substrate
- Sensor Length 10 mm
- Sensor Width 2 mm
- Temperature Sensor Type RTD
- Wire Diameter 0.2 mm
Description
L'élément TFD à résistance de platine constitue une réalisation en film mince miniature permettant d'effectuer des mesures de précision dans les cas où une réponse rapide est nécessaire. La couche de platine est recouverte d'une couche mince en céramique thermo-conductrice et est ainsi très sensible aux variations de température. Il convient en particulier pour les mesures de surface et dans les gaz. La techologie à film mince assure une excellente résistance aux vibrations. Le modèle TFD-ENA est encapsulé dans un composé garantissant la protection contre l'humidité, les fils de connexion pouvant être eux-mêmes protégé par une gaine en silicone.Pour obtenir les caractéristiques complètes de ces produits, consultez la notice commerciale par le lien en bas de cette page.
PDFs & Manuals