1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

PSW2100
Electronic Pressure Switch with OLED Display and Alarm Outputs
Models In Stock
PSW2100
From
C$
757.32
Models In Stock

Product Overview
Show Ratings & Reviews
Do these switches have CRN's?
Thank you for your inquiry, the PSW2100-005C doesn’t have CRN’S .
Date published: 2022-09-19
can it used on a helium supply system.
The wetted parts of this pressure transducer are all 316 Stainless Steel. It would be ok to use with Helium
Date published: 2021-11-10
What is the Emission and immunity to interference standard that applies to PSW2100 switch? For example, EN 61326 or NAMUR NE 21
Thank you for your inquiry. Contacting manufacturing for information on which standard it conforms to. Will forward the information via email to you directly via email
Date published: 2025-01-06
Will this switch work with a 4 pin M-12 connector?
This pressure switch requires a 5-pin M12 female connector. It will not interface with a 4-pin M12.
Date published: 2024-03-22
Just purchased a PSW2100-150C, I'm not getting a 4-20mA output, reads 21.1V open circuit and plugged into an measurement unit. Do I need to enable the output? Signal connection diagram is incorrect, Pin 3 RET pin 5 SIG 2 SW2 4 SW1
You should not have to enable the 4 to 20mA output. A wiring issue may be causing the problem. Reviewing the manual and will make corrections. Advise you contact us at pressure@omega.com with your contact information so we can respond directly with the resolution of this issue
Date published: 2022-11-30
Is this suitable for liquid measurement? The water we are measuring is contaminated with mercury.
The Process Connection Material for the PSW2100-400C is 316L SS, this material is suitable for liquids
Date published: 2021-05-19
Is this product capable of external visual warning/monitoring? As in output wired to 2-3 LEDs a couple feet away that read under pressure, good pressure, and/or overpressure? If not, could you point me in the direction of a product that does. Thank you.
The two on board transistor output can be wired to switch the power being used to drive the unit to also drive external alarm devices.
Date published: 2022-11-21