1-800-663-4209 | Your feedback matters, take a quick survey Website Feedback

LR10-Series
Flowline Radar Level Transmitter for Corrosive Environments
- PFA encapsulated antenna and mount for corrosive media.
- Simple configuration via integral push button display module.
- 26 GHz. pulse radar is unaffected by vapor or condensation.
- 12” (30cm) dead band enables utilization of the entire tank.
LR10-Series
From
C$
2,625.91

Product Overview
- Accuracy ± 5 mm
- Antenna Diameter 1.74 in
- Antenna Length 4.25 in
- Approvals CE, RoHS, cTUVus, FCC
- Bar Graph Percent of Span
- Beam Angle 22°
- Configuration Push Button
- Deadband 12 in
- Display and Indications Echo Signal Curve
- Display Measuring Units ft, m
- Display Type LCD
- Electrical Connection 1/2 in NPT
- Electrical Output 4 to 20 mA
- Enclosure Ratings IP67, NEMA Type 6
- Frequency 26 GHz
- Materials Aluminum, Polycarbonate
- Measuring Range, Min 1 ft
- Memory Non-Volatile
- Number of Wires 2
- Operating Pressure, Max 43.5 psi
- Operating Pressure, Min -14.5 psi
- Power Consumption 22.5 mA
- Probe Type Antenna
- Process Connection Size 1 1/2 in
- Process Connection Type NPT Male and Female
- Process Temperature, Max 130 °C
- Process Temperature, Min -40 °C
- Signal fail-safe 3.9 mA, 20.5 mA, 22 mA
- Signal invert 4 to 20 mA, 20 to 4 mA
- Storage Temperature, Max 80 °C
- Storage Temperature, Min -40 °C
- Supply Voltage 16 to 26 Vdc
- Tank Type Metal / Reinforced Concrete
- Temperature Compensation Automatic
The general purpose 26 GHz. pulse radar level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via its integral push button display module. The non-contact liquid level sensor is intended for chemical or water storage applications in above grade metal or reinforced concrete tanks or below grade tanks of any material. Select this sensor for easy application conditions with corrosive media, light agitation, condensation or vapor, and installation in a low-profile tank adapter or flange fitting. Typical applications include chemical bulk storage and tanker trucks.
PDFs & Manuals
Show Ratings & Reviews
Is there a minimum clearance around the probe head, like the beam diameter on the ultrasonics? Can it be placed into a pipe, what is the minimum diameter?
Thank you for your inquiry about the pulse radar transmitter. It has a 22 degree beam angle and a 12 inch dead band which means you will not measure any liquid level within that distance.
Date published: 2021-06-08