Models In Stock
- Non-invasive temperature measurement
- Mounts to outside of tank, measures fluid inside of tank
- Accuracy comparable to an invasive sensor, ±0.5°C
- Designed for tanks 2 feet in diameter or larger
HTS-HANI-TANK-M
From
C$
1,155.67
Models In Stock

Product Overview
- Accuracy ± 0.5 °C (± 0.9 °F)
- Accuracy Note ± 0.5°C (± 0.9°F) (stainless steel); ± 1.0°C (± 1.8°F) (other metals)
- Applications Chemicals, Clean Water and Purified Solutions, Fluid Measurement and Control, Food and Beverage, Fuel and Gas, General Purpose, Industrial and Manufacturing, Oils, Pharmaceutical, Waste Management
- Base Mounting Metal Tank
- Electrical Connection M12 8 pin Female
- Enclosure Ratings IP65
- Height 1.72 in
- Length 2.6 in
- Loop Resistance (Vsupply -8V)/0.24 A
- Materials Nylon, Silicone, Brass, Stainless Steel
- Media Compatibility Water, Water-based fluids
- Mounting Bolt-On
- Operating Temperature, Max 40 °C
- Operating Temperature, Min 0 °C
- Output Detail 4 to 20 mA User scalable analog output, default scaling 0-100°C
- Process Temperature, Max 100 °C
- Process Temperature, Min 0 °C
- Response Time t63: 5 sec ; t90: 10 sec
- Supply Power Note 8 VDC - 28 VDC (loop powered)
- Supply Voltage 8 to 28 Vdc
- Tank Diameter less than 2 ft
- Width 4.38 in
Non-Invasive Operation
No penetration, no risk of contamination
The HANI™ Tank Sensor never comes into contact with the process media inside of the tank. There is no risk of buildup, sensor wear or breakage from agitators, mixers, or corrosive abrasive liquids.
High Accuracy & Fast Response Times
Performs like an invasive sensor.
Omega’s patent pending Hybrid Temperature Sensing platform uses multiple sensors and a proprietary algorithm to achieve the same accuracy and fast response times as state-of-the-art invasive sensors without the cost and risk.
Accuracy for metal tanks with fluid flowing:
Stainless Steel:± 0.9℉ (± 0.5 °C)Other Metals:± 1.8℉ (± 1.0 °C)
Ease of Installation
- • No drilling
- • No cutting
- • No downtime
Omega’s innovative design makes sensor installation easy. Unlike invasive sensors, HANI™ Tank Sensor mounts to the outside of a metal tank and reads the temperature of the process media inside of the tank.
Works on most tank sizes and materials
The HANI™ Tank Sensor is designed for use on any metal tank 2 feet in diameter or larger. It arrives factory set for stainless steel tank walls, with additional materials selectable through Omega’s free SYNC software.
Common Applications
New and retrofitting existing systems
Lower the total cost of ownership and reduce contamination risk without sacrificing performance by upgrading to a HANI™ Tank Sensor.
Verify existing invasive sensors
With accuracies comparable to most state-of-the-art invasive sensors, the HANI™ Tank Sensor can easily be placed next to an invasive sensor to verify the accuracy or determine the drift of the invasive sensor.