Welcome to our new website, found an issue or bug? Please report it here

LC402
Low Profile, Tension & Compression Load Cells for Industrial Weighing
Models In Stock
- 5-Point NIST Traceable Calibration with
- 59 kOhm Shunt Cal Data Provided
- All Stainless Steel for Harsh Industrial Applications
- 0.25% Interchangeable for Multiple Load Cell Applications
LC402
From
C$
1,431.00
Models In Stock

Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0% (in Compression)
- Bridge Resistance 350 ± 10 Ω
- Cable Length 15 ft
- Calibration Option 5 POINT NIST
- Force Type Compression, Tension
- Full Scale Deflection 0.003 in
- Interchangeability 0.0025
- Load Cell Type Pancake
- Materials 17-4 PH Stainless Steel
- Operating Temperature, Max 121 °C
- Operating Temperature, Min -54 °C
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect 0.0045% FSO/°C
- Thermal Zero Effect 0.0045% FSO/°C
- Zero/Balance Error ± 1%
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ± 0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ± 1% FSO
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
ranges ?400,000 lb: 300% of Capacity
ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ± 10 ?
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately
The LC402 is also available in metric configurations, with ranges from 0-25 to 0-10,000 kgf and metric threads. Please see the LCM402 for complete details, or contact our Pressure department for more information.
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ± 0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ± 1% FSO
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
ranges ?400,000 lb: 300% of Capacity
ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ± 10 ?
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately
The LC402 is also available in metric configurations, with ranges from 0-25 to 0-10,000 kgf and metric threads. Please see the LCM402 for complete details, or contact our Pressure department for more information.
Show Ratings & Reviews
Rated 5 out of
5
by
Richard Pare from
Load cell
Used for setting up Indianapolis and endurance cars.
Date published: 2024-09-29
Rated 5 out of
5
by
Tony Lario from
High quality and value.
Been using this model for years. High quality and value.
Date published: 2023-03-26