OS-HFV50-3001-H1

300:1 FOV, 600°C to 1600°C, Fixed IR Sensor with Display

C$1 434.13

Item# OS-HFV50-3001-H1

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 C$1 434.13
5-9 C$1 362.42
10-24 C$1 333.74
25-49 C$1 276.38
50-99 C$1 247.69
100+ C$1 219.01

In Stock

Lead Time (If not in stock): 10 weeks

Product Specs

<< See all Product Models
Brand
Additional Features 1 Simultaneous analog and digital outputs
Cable Length 3 m
Cable Length Note 3 m (standard, 4-cores), 5 m/10 m
Current Draw 100 mA
Data Interface USB
Emissivity Note 0.100 to 1.000, in 0.001 increments
Emissivity, Max 1
Emissivity, Min 0.1
Enclosure Ratings IP64
Field of view 300:1
Intrisically Safe No
Loop Resistance, Max 500 Ω
Operating Temperature, Max 70 °C
Operating Temperature, Min 0 °C
Output Signal Current
Process Temperature, Max 1600 °C
Process Temperature, Min 600 °C
Relative Humidity Note 10 to 95%, non-condensing
Relative Humidity, Max 95%
Relative Humidity, Min 10%
Repeatability ± 0.3% of reading +1°C
Response Time 5 ms
Response Time Note 5 ms ((95% signal))
Sensor Diameter 59.5 mm
Sensor Length 110 mm
Spectral Response, Max 1 μm
Statistics Average, Peak Hold, Valley Hold
Storage Temperature, Max 80 °C
Storage Temperature, Min -20 °C
Supply Power Note 24 VDC ± 20%
Supply Voltage 24 Vdc
Temperature Resolution 0.1 °C
Weight 500 g
Weight Note 500g (without cable)
See All Specs Show Less
300:1 FOV, 600°C to 1600°C, Fixed IR Sensor with Display OS-HFV50-3001-H1 OS-HFV50-3001-H1
Rated 4 out of 5 by from Good device, bad documentation The product works well, but the operator's manual contains a MAJOR error in the section on how to set up the sensor. The manual says to enter setup mode by pressing and holding both buttons. However, pressing and holding down, then pressing up resets the sensor, erasing all settings. Setup must be entered by pressing and holding up, then pressing down. This is not explained in the manual. It took 6 calls to Omega over two days to even explain to a tech support person what the error was. I hope that it will be corrected in future documentation.
Date published: 2021-02-09
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_OS-HFV50-3001-H1, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
en-CA
en_CA
Save Configuration