MX1105

Choose a Variant

Number of Measurements

C$310.87

Item# MX1105

In Stock

Lead Time (If not in stock): 9 weeks

Product Specs

<< See all Product Models
Brand
Accuracy Note Current Accuracy: ± 0.001 mA ± 0.2% of reading, Voltage Accuracy: 0 to 24 V: ± 1.0 mV ± 0.3% of reading, 0 to 2.5 V: ± 0.1 mV ± 0.1% of reading, 0 to 5 V: ± 0.2 mV ± 0.3% of reading, 0 to 10 V: ± 0.4 mV ± 0.3% of reading
Approvals CE
Battery Size and Type Alkaline AAA
Battery life 1 yr, typical with reading interval of 1 min
Configuration HOBOmobile® app Android, iOS, iPadOS
Current Accuracy ± 0.001 mA
Current Measurement Range 0 to 20.1 mA
Current Resolution 0.3 µA
Data Interface Bluetooth
Display LCD
Display Note LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Enclosure Ratings IP54
Form Factor Note Use the four magnets on the back of the logger to mount it to a magnetic surface or insert the tie wraps through the mounting loops to attach it to other surfaces
Form factor Magnetic Surface or Insert the tie wraps
Height 1.15 in
Input Type External
Length 2.13 in
Logger with Cable Type Current: SD-MA-420 or CABLE-4-20mA; Voltage: 0 to 24 V: SD-VOLT-24 or CABLE-ADAP24; 0 to 2.5 V: SD-VOLT-2.5 or CABLE-2.5-STEREO; 0 to 5 V: SD-VOLT-05 or CABLE-ADAP5; 0 to 10 V: SD-VOLT-10 or CABLE-ADAP10
Logging Modes burst, Fixed interval
Measurement Type Current, Voltage
Memory 4 MB
Memory Modes stop when full, Wrap when full
Memory Note Approximately 4 to 15 minutes depending on the mobile device; may take longer the further the device is from the logger
Number of Measurements 4
Operating Temperature, Max 70 °C
Operating Temperature, Min -20 °C
Radio Power 1 mW
Resistance Resolution Voltage: 384 µV, Current: 0.3 µA
Resolution Note Current Resolution: 0.3 µA, Voltage Resolution: 0 to 24 V, 384 µV, 0 to 2.5 V: 40 µV, 0 to 5 V: 80 µV, 0 to 10 V: 160 µV
Restart Mode Push button
Samples,Max ~1.9M Samples, Interval Selectable 1 sec to 18hrs
Start Modes At set date and time, Button Push, Immediate Start, Next Interval
Stop Modes Button Push, When Memory is Full, At set date and time, At set Duration
Supply Power Type Battery
Time Accuracy ± 1 minute/month
Transmission Range 30.5 m
Voltage Accuracy ± 1.0 mV
Voltage Measurement Range 0 to 2.5 V, 0 to 5.0 V. 0 to 10 V, 0 to 24 V
Voltage Resolution 384 µV
Weight 4.34 oz
Width 4.44 in