Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

FMG550-Series

Hot-Tap Metal Insertion Electromagnetic Flow Meter

Models In Stock
  • Hot-Tap Version for Installation and Service Without System Shutdown
  • Diagnostic Features Using Colored LED Lights
  • Optional Detachable Waterproof Cable
  • Output Choices of Frequency or 4 to 20 Ma
FMG550-Series
From C$ 3,448.18
Models In Stock
Hot-Tap Metal Insertion Electromagnetic Flow Meter FMG550-Series FMG550-Series
loading all models
Product Overview
  • Accuracy ± 2 %, ± 5% with transitional flow
  • Accuracy Note <± 2% of measured value in reference conditions where the fluid is water at ambient temperature, the appropriate upstream and downstream distances are observed, the sensor is inserted at the correct depth, and there is a fully developed flow profile which is in compliance to ISO 7145-1982 (BS 1042 section 2.2). 32 µA maximum error (at 25°C @ 24 Vdc)
  • Approvals CE
  • Cable Length 300 m
  • Conductivity > 20 µS/cm
  • Current Sink, Max 50 mA
  • Enclosure Ratings IP68, NEMA 6P
  • Installation Temperature, Max 40 °C
  • Isolation Low voltage <48 Vac/Vdc from electrodes and auxiliary power
  • Linearity ± 1%
  • Linearity Note ± 1% reading + 0.01 m/s (± 1% reading + 0.033 ft/s)
  • Loop Resistance 300 Ω
  • Materials, Wetted 316 Stainless Steel, FKM, PVC, PVDF, Rubber
  • Media Compatibility Acid Solutions, Conductive Liquids, Saltwater
  • Number of Outputs 1
  • Operating Pressure, Max 300 psi
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -15 °C
  • Output Detail 4 to 20 mA, programmable and reversible, loop
  • Pipe Size, Max 48 in
  • Power Supply Rejection ± 1 µA/V
  • Process Connection Note Standard 1 1/4" NPT Tee Adaptors, Customer Supplied
  • Process Connection Size 1 1/4 in
  • Process Connection Type NPT Female
  • Process Temperature, Max 85 °C
  • Process Temperature, Min -15 °C
  • Pull Up Voltage, Max 30 Vdc
  • Repeatability ± 0.5%
  • Repeatability Note ± 0.5% of rdg @ 25°C (77°F)
  • Short-Circuit Protected < 30 V
  • Short-Circuit Protected Note <30 V @ 0 Ω pull-up for 1 hour, reverse polarity protected to -40 V for 1 hour, over-voltage protected to 40 V for 1 hour
  • Storage Temperature, Max 70 °C
  • Storage Temperature, Min -15 °C
  • Supply Power Type DC
  • Temperature Drift Note ± 1 μA
  • Velocity, Max 33 ft/s
  • Velocity, Min 0.15 ft/s
  • Volumetric Flow Rate, Max 0 GPM
  • Volumetric Flow Rate, Min 0 GPM
  • Weight 0 lb
The FMG-550 Series magmeter flow sensors are heavy-duty, high-performance sensors in an adjustable, insertion configuration that can be used with a ball valve for hot-tap installations. This insertion-style flow sensor has no moving parts and is constructed of corrosion-resistant materials to provide long-term reliability with minimal maintenance costs.

The FMG-550 Series is versatile and simple-to-install, delivering reliable flow measurement over a wide dynamic range. Pipe sizes range from 2 to 48". Omega’s FMG-550 magmeters offer frequency or current outputs. The blind transmitter (4 to 20 mA output) is available for long distance signal transmission. The empty pipe detection features a zero flow output when the electrodes are not completely wetted. The frequency output is bi-directional while the 4 to 20 mA output can be set for uni- or bi-directional flow. The 4 to 20 mA output is factory spanned. Other factory configurations available, see "Notes" below for ordering instructions.

SPECIFICATIONS
Wetted Materials: 316 L stainless steel body and electrodes, PVDF insulator, O-rings (FPM standard), 4-conductor shielded cable, PVC jacket (fixed cable models) or watertight rubber cable with connector on “-SUB” models
Power: 4 to 20 mA (24 Vdc nominal, 21.6 to 26.4 Vdc max, 22.1 mA maximum), frequency (5 to 24 Vdc nominal, 5 to 26.4 Vdc max, 15 mA max), reverse polarity and short circuit protected pipe size of DN50 to DN1200 (2 to 48")
Flow Range: 0.05 m/s (0.15 ft/s) min, 10 m/s (33 ft/s) max
Linearity: ± 1% reading + 0.01 m/s (± 1% reading + 0.033 ft/s)
Repeatability: ± 0.5% of rdg @ 25°C
Minimum Conductivity: 20 µs/cm
Accuracy: <± 2% of measured value in reference conditions where the fluid is water at ambient temperature, the appropriate upstream and downstream distances are observed, the sensor is inserted at the correct depth, and there is a fully developed flow profile which is in compliance to ISO 7145-1982 (BS 1042 section 2.2).
Electrical Current Output: 4 to 20 mA, programmable and reversible, loop
Accuracy: 32 µA max error (at 25°C @ 24 Vdc)
Temperature Drift: ± 1 µA per °C max
Power Supply Rejection: ± 1 µA per V
Isolation: Low voltage <48 Vac/dc from electrodes and auxiliary power
Maximum Cable: 300 m (1000')
Maximum Loop Resistance: 300 ?
Error Condition: 22.1 mA frequency output
Maximum Pull-up Voltage: 30 Vdc
Short-Circuit Protected: <30 V @ 0 ? pull-up for 1 hour, reverse polarity protected to -40 V for 1 hour, over-voltage protected to 40 V for 1 hour
Maximum Current Sink: 50 mA, current limited Temperature/Pressure Ratings
Storage Temperature: -15 to 70°C (5 to 158°F) in non-icing conditions Operating Temperature Ambient: -15 to 70°C (5 to 158°F) in non-icing conditions
Media: -15 to 85°C (5 to 185°F)
Maximum Operating Pressure: 20.7 bar @ 25°C (300 psi @ 77°F)
Hot-Tap Installation Requirements:
Maximum Installation Pressure:
20.7 bar (300 psi)
Maximum Installation Temperature: 40°C (104°F) Hot-tap installation at temperatures that are greater than 40°C (104°F) or with hazardous liquids are not permitted with this product.
Connector: NEMA 6P (IP68)
EN 61326: Immunity and emissions for control equipment
Rated 5 out of 5 by from Fits my needs exactly Exactly the same as competition with mush better value - Comes with everything you need
Date published: 2024-08-30
  • y_2025, m_2, d_21, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_FMG-553, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT

Can fmg-554 be provided with local display aside the transmitter. At how much?

Asked by: Lekan
Thank you for your inquiry about the insertion magnetic flow meter. A remote display such as the DPF64 will display flow rate, the DPF65 will display total volume, and the DPF66 will display both flow rate and total volume and will accept the signal from the FMG-554.
Answered by: Application Engineer JC
Date published: 2022-04-08

What's the frequency range of the FMG553 FLOWMETER, please?

Asked by: Lekan
Thank you for your inquiry. The frequency output is equal to the voltage supplied input and the K-factor is listed in the manual for the pipe dimaeter and construction of material to install the mag meter. Also, it can be determine via an equation provided below: f = (K x Q)/60 where f is the frequency in Hz K is the K-factor in pulses per gallon Q is the flow rate in gallns per minute
Answered by: Application Engineer JC
Date published: 2023-09-19
  • y_2025, m_2, d_20, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_FMG-553, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 3ms
  • QUESTIONS, PRODUCT
en-CA
en_CA
Save Configuration