Welcome to our new website, found an issue or bug? Please report it here
FP1402
DIGITAL PLASTIC PADDLEWHEEL FLOWMETERS

Choose a Variant
Material Construction Option
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 1 % |
Alarm Types | 2 |
Approvals | CE |
Approvals Note | EMC Compliance with 89/336/EEC as amended. Emission Standard: EN 55011:1991, Group 1, Class A Immunity Standard: EN 55082-1:1992 |
Data Interface | RS232 |
Digital Output Note | UCE 40 Vdc, ICE 150 mA |
Display Type | LCD |
Display Type Note | Optional local 2 x 16 characters LCD with adjustable backlight (2 lines of text),Optional 4 pushbutton key pad |
Electrical Output | 4 to 20 mA, 0 to 5 Vdc |
Enclosure Ratings | IP67, NEMA Type 4X |
Material Construction Option | Polypropylene Body |
Materials, Wetted | EPDM, Nickle Tungston Carbide, Polypropylene, Sapphire |
Operating Pressure, Max | 150 psi |
Operating Pressure, Min | 0 psi |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -10 °C |
Output Detail | Linear 0 to 5 Vdc (3000 Ω minimum load impedance); linear 4 to 20 mA (500 Ω maximum loop resistance). Maximum noise 20 mV peak to peak (for 0 to 5 Vdc output); Flow Pulse Output: 3.3 Vdc |
Pressure Drop Note | Maximum Pressure Drop: @ 15 psi for sized units @ 20 psi all other sizes |
Pressure Drop, Max | 1 psi |
Pressure Type | Gauge |
Process Connection Size | 3/8 in |
Process Connection Type | NPT Female |
Process Temperature, Max | 60 °C |
Process Temperature, Min | 0 °C |
Repeatability Error | ±0.25% |
Response Time | 1 s |
Response Time Note | Approx 1 sec (above 10% of full scale flow), approx 2 seconds (below 10% of full scale flow) |
Supply Power Note | 11 to 26 Vdc, 100 mV maximum peak to peak output noise, Consumption: +12 Vdc (150 mA maximum); +24 Vdc (100 mA maximum); circuit board have built-in polarity reversal protection, 300 mA resettable fuse provide power input protection. |
Temperature Accuracy | ± 0.5 °C |
Viscosity Note | 1 cSt (water) can be used for liquids up to 50 cSt with field calibration (max flow range may be affected |
Volumetric Flow Rate, Max | 5 GPM |
Volumetric Flow Rate, Min | 0.5 GPM |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews