iServer2-Probe
iServer 2 - Virtual Chart Recorder
Models In Stock
- Built-in Webserver with Live Charting with Display (Select Models)
- Internal Data Storage up to 10 Years
- Battery Backup
- Dual Omega Link Smart Probe functionality enabled with M12-MT-079-2F and select Smart Probes (see Accessories)
iServer2-Probe
From
C$
1,042.47
Models In Stock

Product Overview
- AC Adaptor Operating Temperature 0 to 40 °C
- Accuracy Note Pressure: Accuracy Over Full Range: ± 6 mbar from 300 to 1100 mbar, Accuracy @ 25 °C: ± 4 mbar from 700 to 1100 mbar
- Alarm Two contact inputs TTL 0.5 mA; one open collector output 150 mA @ 30 V DC
- Approvals CE, UKCA, ICES-3(B)/NMB-3(B), FCC
- Battery Operating Temperature -18 to 55 °C
- Battery Size and Type Alkaline 9V
- Cable Temperature, Max 125 °C
- Cable Temperature, Min -40 °C
- Configuration Internal Web UI
- Data Interface Ethernet, USB
- Data Interface Note Ethernet (RJ45): 1x port (Power over Ethernet available on qualifying models) Supported Protocols: TCP, UDP, SNMP, SNTP, ARP, ICMP, DNS, HTTP, and Telnet
- Electrical Connection M12 8 pin Female
- Form factor Wall Mount
- Height 4 in
- Hysteresis ± 0.8%
- Input Type External
- LED Indicators 100 BASE-T, Network Link and Activity, Internet
- Length 12.99 in
- Logging Modes Fixed interval
- Measurement Type Barometric Pressure, Relative Humidity, Temperature
- Memory 11 GB
- Number of Measurements 3
- Operating Temperature, Max 60 °C
- Operating Temperature, Min 0 °C
- Pressure Accuracy ± 6 mbar
- Pressure, Max 1100 mBar
- Pressure, Min 300 mBar
- Probe Type Smart Probe
- Relative Humidity 0 to 80 % non-condensing
- Relative Humidity Accuracy ± 2.5% RH
- Response Time Temperature: < 1 sec, RH: 8 sec
- Response Time Note Temperature: Less than 1 second, RH: 8 seconds
- Samples,Max 75M Samples, Interval 1 Sample / Second, Continue logging up to 10 000 data points for a period of 96 hours
- Sensor Type Probe
- Software Access web server using any modern web browser such as Chrome, Edge, or Firefox on the same local network; Firmware upgrade from Internet; Export probe data log to CSV files
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Current 1.5 A
- Supply Power Note Back-Up Battery: 9 V DC, alkaline, Power Consumption: 4 W, AC Power Adapter (Included) Nominal Output: 12 V DC @ 1.5 A, Power over Ethernet: IEEE 802.3AF, 44 V - 49 V, Power Consumption under 10 W
- Supply Voltage 9 to 12 Vdc
- Temperature Accuracy ± 0.3 °C
- Temperature Measurement, Max 85 °C
- Temperature Measurement, Min -40 °C
- Temperature Repeatability ± 0.15 °C
- Weight 1.44 lb
- Width 6.13 in
iServer 2: Introduction
The iServer 2 virtual chart recorder offers an intuitive way to collect and display live sensor readings through a web-based user interface or by integrating the device into an existing Omega Link Ecosystem.
The iServer 2 probe variant is packaged in a rugged, compact, stainless-steel housing designed for industrial applications and comes in variants that support different Omega Link Smart Probe types:
M12 Smart Probe VariantsPart Number | iS2-THB-B | iS2-THB-ST | iS2-THB-DP |
---|---|---|---|
Screen | No Display | Display | Display |
Sensor Type | Probe | Probe | Probe |
I/O | No Relay, No DIO | Relay, DIO | Relay, DIO |
Power | AC to 12 VDC Adaptor | AC to 12 VDC Adaptor | AC to 12 VDC Adaptor,PoE |
Web UI and Live Charting
The iServer 2 web UI offers a myriad or configurable features to ensure the device operates at the preferred user preferences. Configurable features include selective data extraction, measurement and device traceability, local alarms, and adaptive transmission rates. Live charting provides real-time readings of probes attached to the iServer 2 unit.
Edge Control and Built in I/O
The iServer 2 features 2 configurable digital I/O and relay ports(Standard and Deluxe models only). These can be used for a myriad of applications including driving relays or physical alarms. The iServer 2 can also be utilized as an edge controller, with autonomous independent decision-making capabilities to generate local alarms or provide control outputs based on sensor inputs.
Alarms and Notifications
A fully configurable alarm system is available in the web UI to create events and thresholds that will trigger a notification should those scenarios be met. A modern notification system allows users to be notified via email or text.
Easy Setup
The iServer 2 is simple to install and use, and features Omega’s iServer technology that requires no special software except a web browser. The iServer 2 connects to an Ethernet Network with a standard RJ45 connector and uses TCP/IP or Modbus TCP protocols to communicate. It is easily configured with a simple menu using a web browser and is password protected. From within an Ethernet LAN, the user simply types the hostname or IP address in any web browser, and the iServer 2 provides a webpage with the current readings.
Typical Applications
The iServer 2 is great for monitoring temperature in applications such as clean rooms, computer rooms, HVAC systems, hospitals, laboratories, semiconductor fabs, electronic assembly, warehousing, museums, manufacturing, farm animal shelters, greenhouses, pharmaceutical, food processing and storage, and many more.
Power Over Ethernet
The iS2-THB-DP variant of the iServer 2 both offer a Power over Ethernet (PoE) feature that provides the device with sufficient power to operate when connected to a PoE Injector or router that supports Power over Ethernet.
Power Failure
The iServer 2 will continue to collect data for 96-hours when powered by a standard 9 Volt alkaline backup battery (included). A failure on the Ethernet network will not interrupt data recording.
Important Note: A fully charged 9-volt battery will allow the iServer 2 to continue logging up to 10,000 data points for a period of 96 hours. When the 10,000 logged data points have been exceeded while running on the backup battery, the oldest logged data point on the Smart Probe will be overwritten starting from the oldest data point saved on the Smart Probe. A logging interval of at least 35 seconds or longer will prevent the overwriting of data during the 96-hour period the battery is in use.Omega Link Integration
Omega Link compatible devices, such as the iServer 2, can be added to an existing Omega Link Ecosytem to provide data anytime, anywhere, through the Omega Link Cloud. The following Omega Link Smart Probes are supported:
Part Number | Description |
---|---|
SP-003/SP-004 | Temperature, Humidity, Barometric Pressure, Dewpoint, Humidex, and Heat Index Smart Probe with discrete I/O |
SP-005 | Temperature and RTD Smart Probe |
SP-006 | Pressure Monitoring and Control Smart Probe |
SP-010 | Load Cell Smart Probe |
SP-014 | Process Monitoring Smart Probe |
SP-016 | Heat Flux Smart Probe |
View the full list of Omega Link Smart Probes.
Important Note:The use of additional Omega Link Smart Probes will require a firmware update of the Smart Probe. The iServer 2 web interface is capable of downloading and updating the firmware of any Smart Probe that is compatible with the iServer 2.Dual Probe Functionality
Dual probe functionality can be enabled on the iServer 2 when two Omega Link Smart Probes are connected to the iServer 2 using an Omega M12-MT-079-2F Y-splitter cable, sold separately. An iServer 2 firmware upgrade to the latest version is required to enable dual probe functionality. A firmware upgrade video tutorial is available here and a PDF guide is available in the Manuals & Downloads section of this product page. Refer to the full list of compatible Omega Link Smart Probes in the Accessories section.
CAL-3 SKU’s
CAL-3 is available for iServer 2 M12 Models for temperature and humidity only by ordering the SKU’s below. For Barometric Pressure or additional calibration requirements, please contact Omega.
Specifications
INTERFACESAvailable input ports will vary by iServer 2 model.

Ethernet (RJ45):1x port (Power over Ethernet available on qualifying models)
Supported Protocols:TCP, UDP, SNMP, SNTP, ARP, ICMP, DNS, and HTTP
Omega Link Smart Probe: 1x M12 8-Pin port
Digital I/O and Relays (Standard and Deluxe Models Only):Two contact inputs TTL 0.5 mA with 10k pull-up; one open collector output 150 mA @ 30 V DC
LED Indicators: 100 BASE-T, Network Link and Activity, Internet
Alarm I/O: Two contact inputs TTL 0.5 mA with 10k pull-up; one open collector output 150 mA @ 30 V DC
Sample Rate: 8 samples/second max
Memory Capacity and Sample Rate: The table below lists the lifespan of the internal storage before the 11 GB of storage is filled. Some Smart Probes come with more than one active sensor. These sensors can be individually enabled and disabled using Omega’s SYNC configuration software.
Sample Rate | 4 Active Sensor |
---|---|
1 second (max) | 2 years |
5 seconds | 12 years |
10 seconds | 20 years |
Management:Device and probe configuration and monitoring through embedded WEB server
Embedded WEB Server:Servers WEB pages containing real-time data and live updated gauge views and charts within definable time intervals
MECHANICAL
Dimensions of Base Device: 101.6 mm L x 155.6 mm W x 330 mm H (4 in. L x 6.13 in. W x 12.99 in. H) not including bracket and M12 connector
Material:Stainless Steel
Display: LCD 32 mm L x 93.5 mm W
Weight: 655 g (1.44 lbs.), including battery
POWER
Power Input:9 to 12 V DC
Consumption: 4W
AC Power Adapter (Included) Nominal Output: 12 V DC @ 1.5 A
Power over Ethernet: IEEE 802.3AF, 44 V - 49 V, Power Consumption under 10 W
Input: 100 to 240 V AC, 50/60 Hz
Back-Up Battery: 9 V DC, alkaline. 96 hours at 5 seconds recording intervals and 1 second reading
ENVIRONMENTAL
Operating Temperatures - iServer 2
iServer 2 Unit:0 to 60°C (32 to 140°F)
Battery: -18 to 55°C (-0.4 to 131°F)
AC Power Adapter: 0 to 40°C (32 to 104°F)
Industrial Cable: -40 to 125°C (-40 to 257°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
GENERAL
Configuration: Internal Web UI
Software: : Access web server using any modern web browser such as Chrome, Edge, or Firefox on the same local network; Firmware upgrade from Internet; Export probe data log to CSV files
Agency Approvals: CE, UKCA, FCC (Part 15, Subpart B, Class B of the FCC rules)
SP-003-1 PROBE ACCURACY SPECIFICATIONS(Included with iServer 2 M12 Smart Probe variants)
Temperature Range:-40 to 85°C (-40 to 185°F)
Accuracy at 25°C:± 0.3°C (± 0.6°F)
Response Time: Less than 1 second
Temperature Coefficient: : less than 0.01 C/C
Repeatability: ± 0.15°C
Relative Humidity
Accuracy at 25°C: ± 2.5% (0 to 80%) non-condensing, ± 3.5% (80 to 100%) non-condensing
Hysteresis: ± 0.8%
Response Time: 8 seconds
Barometric Pressure
Accuracy Over Full Range: ± 6 mbar from 300 to 1100 mbar
Accuracy @ 25°C:± 4 mbar from 700 to 1100 mbar
For full SP-003-1 specifications, navigate to the full product page of SP-003-1.
This product is for sale only in the US, Canada, the UK and EU member countries. At this time, Product does not meet regulatory compliance requirements outside of the aforementioned regions.
PDFs & Manuals
Show Ratings & Reviews
How to get rid of solid red light after setting with static IP address? Factory reset multiple times and cannot get to connect once configured statically
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2024-07-29
Can the iServer 2 communicate with a client using ASCII commands over Ethernet similar to the iServer MicroServer (M4221.pdf, section 4.5.3 - SRTC, SRHb, SRH2 etc)?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2024-11-04
how to communicate i server 2 in labview to read Baro, temperature and humidity? what are the command sets
. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2024-07-29