Welcome to our new website, found an issue or bug? Please report it here

XC-K-TC-WIRE
K Type Thermocouple Duplex Wire
Models In Stock
- High Quality Type "K" Thermocouple Grade Wire
- In Stock - Available for Immediate Shipment
- Choice of Insulation, Wire Gage, & Length
XC-K-TC-WIRE
From
C$
28.00
Models In Stock

Product Overview
- Alloy Material (-) Alumel
- Alloy Material (+) Chromel
- Process Temperature, Min 0 °C
- Thermocouple Type K
- Use With Sensor Type Thermocouple
ANSI Color Code K Type thermocouple wire: Positive Wire, Yellow ; Negative Wire, Red; Overall, Brown
Use the table below as a guide for types available. The "To Order" box contains some examples of popular models. Use the "Part Number Builder" (Below Table) to get pricing for all available models.
Use the table below as a guide for types available. The "To Order" box contains some examples of popular models. Use the "Part Number Builder" (Below Table) to get pricing for all available models.
|
†Weight of spool and wire rounded up to the next highest lb. (does not include packing material).
††Overall color clear
*Has color tracers on jacket and conductors
**Has color tracers on jacket and positive leg only
Some wires available with Special Limits of Error; consult Sales for pricing and availability.
Description
Code couleur IEC :Fil positif, vert ; fil négatif, blanc; ensemble, vert
OMEGA Engineering n'utilise pas le PFA ou PVC retraité dans la fabrication des fils thermocouples.
Veuillez utiliser le tableau ci-dessous comme guide pour les types disponibles. Le tableau "Pour commander" contient quelques examples de modèles courants. Veuillez utiliser le "Tableau constructeur de référence" (ci-dessous) pour obtenir les prix des autres modèles disponibles. Utilisez le tableau ci-dessous comme guide pour les différents types.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
JimboIndy from
Holds up to elevated temperatures
Purchased this wire about three weeks ago for an upcoming U.L. test. Insulation held up very well to temperatures of 600 to 800°F. I thought the test conditions, heat/grease/mechanical abuse, would destroy the thermocouples and that they would need to be replaced for each test run. I was wrong. They survived several test runs and are still usable.
Date published: 2017-08-04
Rated 5 out of
5
by
CandiO from
Easy & effiecient!
I buy a superior quality wire from OMEGA and I am impressed with the ease of ordering.
Date published: 2016-03-01
Rated 3 out of
5
by
roundup from
Sturdy Extension Wire
The wire was very solid which worked well for durability purposes. This feature made it difficult to properly connect the wire to miniature k-type connectors.
Date published: 2016-10-17
Rated 3 out of
5
by
Too much from
A bit overpriced....
A bit overpriced for the quality of the wire. It was not an easy product to work with.
Date published: 2017-06-06
Rated 5 out of
5
by
Ricky from
Excellent product
Buy this from Omega all the time, never a problem.
Date published: 2018-01-02
Rated 5 out of
5
by
Anonymous from
Cable for thermocouple
This cable is very good for extensions or thermocouple construction.
Date published: 2024-08-19
Rated 5 out of
5
by
CCEC Tom from
My Go To Source
In stock and fast shipping of hard to find specialty items
Date published: 2024-06-03
Rated 2 out of
5
by
Dinah from
Wire
The wire is fine, however the outer sheathing isn't brown, it's green. I was assured that this would come in Green and White for the chromel/alumel and the sheathing would be brown.
Date published: 2024-05-29
Can this wire be reused? If so, how many times? Going up to 1225°F.
Thank you for your request. This wire's insulation is rated for physical exposure up to 392°F.
Date published: 2019-10-18
Hi, what would be the most sutable type of thermocouple wire to be used for measuring a temperature around -5c to +5c ? I was planning to use the HH-25U or HH12C readout. Is Type T is more accurate than K or J for example?.
Thank you for your inquiry. At low temperatures, Type T is the most accurate of all thermocouple types.
Date published: 2020-05-10
Hi I am looking at purchasing a spool of TT-K-24-500 and I need it calibrated How do I go about doing this?
Hello,
If you need the wire with a calibration certificate you can order as part number TT-K-24-500-CAL-3.
Date published: 2024-10-24
Hi, Is the wire compatible with organic/week acidic solution of chemical reaction to measure the temperature of the solution?
Hi Pawan,
The thermocouple alloys may contaminate your process. For this I would recommend HSTC series; hermetically sealed in PFA thermocouples.
https://www.omega.com/en-us/temperature-measurement/temperature-wire-sensors/hstc/p/HSTC-TT-20S-65
Best regards,
OMEGA
Date published: 2021-06-01
Nominal size is given as 0.050*0.086 in. What is it mean? how to read this ? I am looking for individual wire OD and overall cable for PR-K-24 part no.
Thank you for your inquiry. The nominal size is the size of the oval shaped cross section of the wire with the overall insulation. We do not provide the individual wire OD.
Date published: 2024-03-20
What's the minimum bend radius?
Thank you for the inquiry. Please allow for 5 to 7 diameters of the wire (narrow side dimension).
Best regards
OMEGA
Date published: 2020-08-12
Hi, Is compatible with OM-CP-OCTTEMP-A? Regards
Hi, thank you for your question. OM-CP-OCTTEMP-A if definitely compatible with type K thermocouples. If you are making your own thermocouples with this wire, please remember to use miniature connectors (like SMPW-K-M) to plug directly into your logger.
Date published: 2020-06-17
Can thermocouple wiring be cut to length?
Thank you for your inquiry. Yes it can be cut to length.
Date published: 2024-10-05