Skip to search Skip to main content Skip to navigation

Welcome to our new website, found an issue or bug? Please report it here

We noticed you are from . Visit your local site for regional offers and live support.

ILD24-UTP

C$1 746.25

Item# ILD24-UTP

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 C$1 746.25
5-9 C$1 658.94
10-24 C$1 571.63
25-49 C$1 484.31
50-99 C$1 397.00
100+ C$1 309.69

In Stock

Lead Time (If not in stock): 6 weeks

Product Specs

<< See all Product Models
Brand
A/D Conversion Dual slope
Accuracy ± 0.5 °C
Accuracy Note ±0.5°C temperature; 0.03% rdg
Common Mode Rejection 120 dB
Current Measurement Range 0 to 20 mA
Decimal Selection 0, 0,001, 0,01, 0,1
Digital Filter Programmable
Display Size 57.2 mm (2.25 in)
Display Type 4 Digit Single LED
Display Type Note 4-digit, 7-segment LED 57.2 mm (2.25") or 101.6 mm (4.00") red, green and amber programmable colors for process variable, set point and temperature units
Enclosure Ratings NEMA Type 1
Excitation Voltage Note Optional in Place of Communication
Impedance Input 10 MΩ for 100 mV, 1 MΩ for 1 or 10 Vdc
Input Configuration Single-ended
Input Type Thermocouple, RTD, Thermistor, Current, Voltage
Length 289 mm
Linearization Points None
Normal Mode Rejection 60 dB
Number of Inputs 1
Offset Adjustment -1999 to +9999
Operating Temperature, Max 40 °C
Operating Temperature, Min 0 °C
Polarity Unipolar
Power Consumption 22.5 W
RTD Type 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; α= 0.00385 or 0.00392
Reading Rate 3 samples/sec
Relative Humidity 90% RH non-condensing
Resolution 1°/0.1°; 10 µV process
Sampling Rate 3 Hz (3 updates/second)
Sensor/Transmitter Power 24 Vdc @ 25 mA
Set Point Adjustment -1999 to 9999 counts
Span Adjustment 0.001 to 9999 counts, programmable
Step Response 0.7 sec for 99.9%
Supply Power Note 100 to 240 Vac ±10%, 50/60 Hz 22.5 W
Supply Power Type AC
Supply Voltage 100 to 240 Vac
Temperature Stability RTD: 0.04°C/°C ;Thermocouple @ 25°C (77°F): 0.05°C/°C, cold junction compensation ;Process: 50 ppm/°C ;
Thermocouple Lead Resistance, Max 100 Ω
Thermocouple Type J, K, T, E, R, S, B, C, N, L
Voltage Measurement Range 0 to 100 mV, 0 to 1 V, 0 to 10 Vdc
Warm-Up to Rated Accuracy 60 min
Width 137 mm
See All Specs Show Less