FMA-1603A

Choose a Variant
Electrical Output
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 0.8 % |
Accuracy Note | ± (0.8% of rdg + 0.2% FS) |
Additional Features 1 | Power Supply Included |
Calibration | NIST 5-Point Certificate |
Data Interface | RS232 |
Display Type | LCD |
Electrical Connection | 8-pin mini DIN |
Electrical Output | 0 to 5 V |
Height | 4.1 in |
Humidity Range | 0 to 100% RH non-condensing |
Materials, Wetted | Aluminum, Brass, Epoxy, FKM, Glass, Gold, Silicone, Stainless Steel |
Measurable Flow Rate | 125% |
Media Compatibility | Air, Gases, Nitrogen, Oxygen |
Operating Pressure, Max | 145 psi |
Operating Pressure, Min | 0 psi |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | -10 °C |
Output Signal | Voltage |
Pressure Drop, Min | 1 psi |
Process Connection Size | #10 |
Process Connection Type | UNF Female |
Repeatability | ± 0.2% |
Response Time | 10 ms |
Response Time Note | 10 ms typical default response time for 63.2% of a step change. A variable register allows response time to be field adjustable to a certain extent via RS232 communications. The primary trade-off for response time is signal noise |
Span Shift | 0.02% FS/°C/atm |
Supply Current | 35 mA |
Supply Power Note | 35 mA typical current draw; 100 mA available supply recommended |
Supply Voltage | 7 to 30 Vdc |
Turndown Ratio | 200:1 |
Volumetric Flow Rate, Max | 10 SCCM |
Volumetric Flow Rate, Min | 0.05 SLM |
Width | 1.1 in |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 4 out of
5
by
Ehgid from
Good Mass Flowmeter
Easy to setup and reliable. Easy to use. Remote operation needs expert installation but is easy to use after setup. Price could be lower to have a broader application.
Date published: 2016-11-17
Rated 5 out of
5
by
Kramers31 from
Flow meter
Omega flow meter works as described for use in a test laboratory
Date published: 2025-01-26
Rated 5 out of
5
by
Duc VuLuong from
Accurate and reliable
Bought this flow meter to measure and calibrate the flow rate of Helium and Argon for a protein analyzer instrument. Without the meter, it's virtually impossible to know the exactly flow rate to calibrate it since the instrument doesn't response to change in flow rate. We waste a lot of precious Helium gas due to that. Now that it's calibrated, we can save money in the long run. Awesome!
Date published: 2024-07-31
Rated 5 out of
5
by
Prof YUYE J TONG from
High performance flow meters
My laboratory have ordered 2 1617A and 4 1619A flow meters and been satisfied with their performance.
Date published: 2023-12-17
Rated 3 out of
5
by
Evan121212 from
Need better software
IT works well, but would love to see a better user interface to connect it to PC. Using PuTTY kind of sucks.
Date published: 2023-08-07
Rated 5 out of
5
by
Shan from
Highly recommend
Great product! I was worried this wouldn't arrive in time for when it was needed but very quick!
Date published: 2023-07-26
Rated 5 out of
5
by
Jon F from
As Advertised
Worked as advertised. No issues. seems robust for out testing environment
Date published: 2023-03-20
Rated 3 out of
5
by
chuckd from
2 units defective out of box
The negative terminal was shorted to the body of the sensor and would not work unless the sensor was installed isolated from ground, which we couldn't do in our application. They are easy to disassemble, and the problem was obvious, as one of the wires that connects to the terminal extended about 1/2" past the point that it was soldered at, so the bare wire came into contact with the body of the sensor when it was assembled.
Date published: 2023-01-05