Welcome to our new website, found an issue or bug? Please report it here
DPGM409-001BDWU
-1 to 1 bar, Compound Gauge

Choose a Variant
Proof Pressure
Pressure Type
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-9 | C$2,317.06 |
10-24 | C$2,201.21 |
25-49 | C$2,154.87 |
50-99 | C$2,062.18 |
100+ | C$2,015.84 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy Class | < 0.1% |
Accuracy Note | ± 0.08% BSL 0.08% typical (0.15% maximum in RF field @ 10V/m) |
Battery Size and Type | 3.6V Li-ion |
Battery life | up to 4 yr |
Cable Length | 2.7 m |
Cable Length Note | 2.7 m (9') with ferrite core (included) |
Compliance | CE |
Data Interface | USB |
Data Interface Note | USB connection for set-up, cable included |
Display Type | LCD |
Display Type Note | 4-digit LCD with user selectable backlighting, (9999 count) 25 mm (1') character height. |
Electrical Output | 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc |
Electrical Output Note | User selectable 0 to 5 Vdc, 0 to 10 Vdc or 4 to 20 mA (external 24 Vdc power supply required) Notes: 1. Bidirectional ranges have a unidirectional analog output equal to their full span; i.e. -15 to +15 psi = 0 to 10 Vdc. 2. Analog output is independently scalable Set jumper to Select Current or Voltage: Software selection of 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA |
Enclosure Material | 316 Stainless Steel |
Enclosure Ratings | IP65, NEMA Type 4X, Weatherproof |
Hi-Side Containment Pressure | 3000 psi |
Isolation between Case and Output Terminations, Min | 100MΩ @ 50 Vdc |
Length | 89 mm |
Line/Static Pressure | 500 psi |
Line/Static Pressure Note | 500 psi maximum applied to both sides simultaneously |
Materials, Wetted | 316 Stainless Steel |
Number of Batteries | 1 |
Number of Digits | 4 |
Operating Temperature, Max | 66 °C |
Operating Temperature, Min | -18 °C |
Output Signal | Current, Voltage |
Pressure Accuracy | ± 0.08 % |
Pressure Cycles | 1 million minimum |
Pressure Type | Differential |
Pressure, Max | 1 bar |
Pressure, Min | 0 mBar |
Process Connection Size | 1/4 in |
Process Connection Type | BSPP Male |
Proof Pressure | 4x Full Scale |
Sample Display Rate Note | User selectable from 0.38 to 30 seconds (preset to 1/second) |
Sample/Display Rate | 0.38 to 30 seconds |
Sensor Dimension Note | 72 to 89 mm L (2.8 to 3.5") below display, 80 mm (3.1") wide" |
Settable Parameters | Backlight, Min, Max, Zero, Clear |
Software Compatibility | Requires Windows® 7 (32 bit); XP, Vista |
Software Settings | Software Settings (via USB) (USB connection is for set-up only) Units: psi, inHg, inH2O, bar, mbar Lock: Allows the lock-out of front panel functions Alarms: User selectable “High” and “Low” alarm limits (open collector) Backlight: On/Off, 10 seconds, 30 seconds, 1 minute, 5 minute Wireless Transmitter (Optional): Channel number, transmission rate, alarms, sensor offset, chart recording, data logging Calibrate: Zero and Span Overrange Indication: “_ _ _ _” |
Stability | ± 0.1% |
Storage Temperature, Max | 82 °C |
Storage Temperature, Min | -40 °C |
Supply Power Note | Battery Note:One 3.6V lithium 8.4 Ah capacity (C cell) included (two included with wireless option) (replacement battery model no. BATT-C-3.6V) |
Supply Power Type | Battery |
Thermal Effects | Zero Balance:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span Span Setting:Ranges 25 mb to 70 mb: ± 1% spanRanges >70 mb: ± 0.5% span |
Weight | 1 kg |
Weight Note | 1 kg (2.2 lb) typical depending upon configuration |
Width | 80 mm |
Wireless Band | None |
Wireless Option Specifications | Transmit Sample Rate: User programmable from 1 sample/2 min to 1 sample/2 sec Radio Frequency (RF) Transceiver Carrier: ISM 2.4 GHz RF Output: 10 dBm (10 mW) Range of RF Link: Up to 120 m (400') outdoors (line of sight); Up to 40 m (130') indoors/urban Included Software: Requires Windows® 7 (32 bit); XP, Vista Data Transmission to Host: Pressure reading, ambient temperature reading, RF transmit strength and battery level. |
See All Specs |