Welcome to our new website, found an issue or bug? Please report it here

LC703
Miniature, Low Profile, Tension & Compression Load Cells
Models In Stock
- Low Profile
- High Accuracy
- Rugged Industrial Design
- Tension or Compression Operation
LC703
From
C$
689.34
Models In Stock

Product Overview
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Cable Length 12 ft
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Electrical Output 2 mV/V
- Enclosure Ratings IP54
- Force Type Compression, Tension
- Full Scale Deflection 0.003 in
- Hysteresis ± 0.15%
- Input Resistance 360 Ω min
- Load Cell Type Pancake
- Operating Temperature, Max 82 °C
- Operating Temperature, Min -40 °C
- Output Resistance 350 ± 10 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Repeatability ± 0.05%
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Supply Voltage 10 Vdc
- Thermal Span Effect ± 0.005% FSO/°F
- Thermal Zero Effect ± 0.005% FSO/°F
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 1%
The LC703 Series is an economical universal (Tension/Compression) load cell with an extremely low profile. Ranges above 100 lb are Stainless Steel; 100 lb and below are Aluminum. The LC703’s low profile, economical price and rugged design make it suitable for many industrial applications including robotics, automated weighing systems or as part of a batch-process control system.
The LC703 is also available in metric configurations, with 0-5 to 0-500 kgf ranges and metric threads. Please see the LCM703 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc (15V max)
Output: 2 mV/V nominal
5-Point Calibration: 0%, 50%, 100%, 50%, 0%
Linearity:
10 to 100 lb: ± 0.15%
>100 lb: ± 0.10 FSO
5 to 50 kgf: ± 0.15%
75 to 500 kgf: ± 0.10%
Hysteresis:
10 to 100 lb: ± 0.15%
>100 lb: ± 0.10 FSO
5 to 50 kgf: ± 0.15%
75 to 500 kgf: ± 0.10%
Repeatability: ± 0.05%
Zero Balance: ± 1.0% FSO
Operating Temp Range: -40 to 82°C (-40 to 180°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.005% FSO/°F
Span: ± 0.005%% FSO/°F
Protection Class: IP54
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Output Resistance: 350 ± 10 ?
Input Resistance: 360 ? minimum
Full Scale Deflection: 0.08 mm (0.003") nominal
Construction:
?100 lb: Aluminum
>100 lb: 17-4 PH stainless steel
?50 kg: Aluminum
>50 kg: 17-4 PH stainless steel
Electrical: 3.6 m (12') shielded 4-conductor PVC cable
The LC703 is also available in metric configurations, with 0-5 to 0-500 kgf ranges and metric threads. Please see the LCM703 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc (15V max)
Output: 2 mV/V nominal
5-Point Calibration: 0%, 50%, 100%, 50%, 0%
Linearity:
10 to 100 lb: ± 0.15%
>100 lb: ± 0.10 FSO
5 to 50 kgf: ± 0.15%
75 to 500 kgf: ± 0.10%
Hysteresis:
10 to 100 lb: ± 0.15%
>100 lb: ± 0.10 FSO
5 to 50 kgf: ± 0.15%
75 to 500 kgf: ± 0.10%
Repeatability: ± 0.05%
Zero Balance: ± 1.0% FSO
Operating Temp Range: -40 to 82°C (-40 to 180°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: ± 0.005% FSO/°F
Span: ± 0.005%% FSO/°F
Protection Class: IP54
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Output Resistance: 350 ± 10 ?
Input Resistance: 360 ? minimum
Full Scale Deflection: 0.08 mm (0.003") nominal
Construction:
?100 lb: Aluminum
>100 lb: 17-4 PH stainless steel
?50 kg: Aluminum
>50 kg: 17-4 PH stainless steel
Electrical: 3.6 m (12') shielded 4-conductor PVC cable
PDFs & Manuals
Show Ratings & Reviews
Rated 1 out of
5
by
febgartnghm dghm from
Nope
No information about the thread size came with the device, On line info onsite is incorrect.
Date published: 2022-03-21
Rated 5 out of
5
by
decline to name from
review
performs as advertised. that's all you want in a load cell, so no complaints
Date published: 2023-04-26
How should these load cells be mounted? Is it alright to tighten bolts down into the tapped holes on either side? Is it alright to tighten a nut down onto the top and bottom surfaces? Or must the load only be applied to the threads?
The load is measured through the threads. If you are using the load cell in compression and are installing something like a load button into the active side threads you would want to leave a slight gap between the bottom of the load button and the surface of the load cell to allow for the deflection of the cell when loaded. Typical deflection would be 0.003"
Date published: 2021-08-07
For the model LCM703-50, what is the unit for the reading after connecting it to the CN16PT controller. Is it in lbs, kg... And for Platinum Monitor, what is the meaning of values and % in the graphing option when connected to LCM703-50
The LCM703-50 is a +/- 50 Kilogram load cell. The CN16PT has a scalable display that you can scale to whatever units of measure you wish within the constraints of 4 Digit display (-9999 to +9999 counts). It also has a movable decimal point if you require your display reading to be in 0.1, 0.01 or 0.001 resolution
Date published: 2021-08-27
The data sheet states that the load cell is calibrated in tension. Is there a way to get it calibrated for compressive use?
Hello,I am sorry, we are unable to calibrate this load cell in compression. You may however use this load cell in compression. If you need more assistance kindly email us at pressure@dwyeromega.com
Date published: 2023-11-01
Are these load cell units calibrated/certified for a certain period of time? Is there a calibration process that can be performed when the calibration/certification expires?
Thank you for you question?
The parts are stored in a controlled environment and would be nominally certified a year from installation.
The calibration can not be done in the field for these units.
Would need to be returned to Omega for re calibration
Date published: 2020-04-29
I have a customer who purchased the LC703-100 load cell and the standard cable length is 12'. Is 12' feet the maximum recommended length or can they extend the cable? If yes, what is the maximum length you recommend?
Thank you for the inquire
You can extend the cable. You will need to re calibrate after the extension .
There is no reamended extension length. Rule of thumb is 2 x max so that's 24 feet.
Date published: 2022-03-04
Do you need an amplifier for a LC-703-150? If so, part #? Thank you
Hello, if you can work with a mV signal you don't need an amplifier. If you need amplified signal such as volts or mA you could consider the DMD4059
Date published: 2023-10-05
On the LC703, which side is the active side? How is it different from the other side?
The active side of load cell one that is farther away from screws on the side of the load cell. The threads on that side react with the internal strain gage element
Date published: 2021-09-01
For the LC703-1K, is the sensing element a single resistor, a pair of resistors, or a four element bridge?
Element is a full (4 element) bridge
Date published: 2021-09-03