Product Overview
- Alarm modes Active High Output, Active Low Output, Adjustable
- Battery life up to 5 yr
- Chart Diameter 254 mm
- Chart Note Chart Span: Bottom and top of span, -9999 to 9999 units; Chart Drive: DC Stepper Motor; Chart Drive: Stepper Motor
- Chart Speed 0.1 to 999.9 Hours
- CMRR 90 dB minimum; 24 Vac maximum for RTD input; 15 Vac maximum for other inputs
- Current Measurement Range 4 to 20 mA
- Cutout Dimensions 321 x 343 mm
- Deadband Recording: 0.3%
- Display Note Digital Displays: 2 possible: 1 per installed pen; (4) 7-segment digits, 14 mm (0.56”) high, red LEDs, automatic (-) positioning, decimal point positioning Keypad: Located on front cover, tactile feedback membrane keys, Display/Record Filter: 1 to 20 Scans. Alarm Display: 2 alarm indications possible per pen; ALRM1 and ALRM2; red LEDs; single ALRM indication provided for controller pens
- Display Type LED
- EMC Standard IEC 61000-4-2
- Filter 1 to 20 Scans
- Height 335 mm
- LED Indicators LED indicates Out 1, Out 2, Man, Ramp, Soak, Seg 1 through Seg 6, process units as applicable
- Length 92 mm
- Materials Plexiglass
- Measurement Range Note Thermocouple: J: 0 to 760°C, K: 0 to 1360°C, T: -220 to 400°C, E: 0 to 750°C, N: 0 to 1300°C, R: 200 to 1650°C, S: 200 to 1650°C, B: 200 to 1800°C, C: 200 to 2300°C RTD: -140 to 400°C Current: 4 to 20 mA Voltage: 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Measurement Type Thermocouple, RTD, Current, Voltage
- NMRR 85 db @ 60 Hz or greater
- Operating Temperature, Max 55 °C
- Operating Temperature, Min 0 °C
- Pen Type Disposable Fiber tip
- Power Consumption 25 VA
- Relative Humidity 0 to 90% RH, non-condensing
- Resolution Pen Resolution: 0.15%
- Response Time 20 sec
- RTD Type 100 Ω Pt sensor; α= 0.00385
- Sampling Rate 1 Scan/sec
- Sensor Break Detection Sensor Fault Detection: Displays “Hi” or “Lo” process input (10% above or below range) and sensor break “SnSr”; pen action on error condition is user configurable to 0 or 100% of chart span; on/off outputs go “off”; proportional outputs go to user-defined value from 0 to 100%
- Standard Limits of Error Error Limit: Measurement Error Limit: Thermocouple Types J, K, T, E, N and RTD: ±0.25% of reading + 1° @ 25°C (77°F); Type R, S, B, C Thermocouples: ±0.25% of span @ 25°C (77°F); mVdc and Vdc: ±0.25% of scaled span plus 1 least-significant digit Ambient Temperature Error Limit: 0.01% of span per °C (1.8°F) deviation from 25°C (77°F) Process Value Output Error Limit: ±0.5% of span Record Error Limit: ±0.5% of chart span or better, typically; ±1.0% of chart span maximum; Calibration Shift: Self-compensating for ambient temperature; all calibration values are stored in memory; Process Value Output Error Limit: ±0.5%; Record Error Limit: ±0.5%
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 115 Vac ±10%, 50/60 Hz
- Supply Power Type AC
- Switch Rating 2 A @ 115 Vac, 1 A @ 230 Vac
- Switch Type SPST
- Temperature Measurement Range J: 0 to 760°C, K: 0 to 1360°C, T: -220 to 400°C, E: 0 to 750°C, N: 0 to 1300°C, R: 200 to 1650°C, S: 200 to 1650°C, B: 200 to 1800°C, C: 200 to 2300°C, RTD: -140 to 400°C
- Thermocouple Type J, K, T, R, S, N, E, B, C
- Vibration 0.5 to 100 Hz @ 0.2 g
- Voltage Measurement Range 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
- Weight 9.1 kg
- Width 384 mm
- Wire Code Option 2- or 3- Wire
The CT7000 microprocessor-based circular chart recorder measures, displays, records, and controls up to two process variables from a variety of inputs. Record and control functions, alarm settings and other parameters are easily configured via the keys on the front cover and self-prompting displays. The CT7000 offers a 250 mm (10") circular chart and 4-digit LED display(s). Display resolution and filters are user configurable.
Two alarm settings are provided for each pen. Each alarm is user configurable as process high or low, deviation from setpoint (above or below), or deviation band (open or closed within band). An alarm hysteresis adjustment is user configurable. Optional control capability includes on/off and PID control. Output type selections include SPST relay, SSR driver and 4-20 mAdc (user configurable to 0-20 mAdc). Also, 4-20 mAdc outputs may be used for retransmitting the process value. Digital communications is optional.
Use the "Part Number Builder" below to get pricing for chart paper.
Two alarm settings are provided for each pen. Each alarm is user configurable as process high or low, deviation from setpoint (above or below), or deviation band (open or closed within band). An alarm hysteresis adjustment is user configurable. Optional control capability includes on/off and PID control. Output type selections include SPST relay, SSR driver and 4-20 mAdc (user configurable to 0-20 mAdc). Also, 4-20 mAdc outputs may be used for retransmitting the process value. Digital communications is optional.