CWM-HEATCABLE
200 °C Max Constant Wattage Heating Cable 120-480 Vac
Models In Stock
- Constant Output
- Cut to Any Length
- Lower Installation Costs
- Flexible
CWM-HEATCABLE
From
C$
14.50
Models In Stock

Product Overview
- Additional Features 1 Tinned Copper Overbraid
- Bend Radius, Min 6 times minor diameter
- Cable Length 1 ft
- Cable Length, Max 200 ft
- Cable Material Copper
- Circuit Breaker Note To determine the circuit breaker size required, divide the W/ft (at operating voltage) by the operating voltage; multiply the result times the total installed cable length in feet; multiply this result times 1.2 to get the minimum circuit breaker size
- Heater Wire Material Nichrome
- Insulation 11 Mil FEP Overcoat
- Module Length 12 in
- Operating Temperature Note Steam Cleaning: CWM can withstand 200°C (392°F), 150 psig steam purging of process piping when not energized; Exposure Temperature: 0 to 200 °C
- Purchase Note Use quantity to indicate length of cable to purchase (increments of 1 foot), min purchase of 25 ft
- Weight 110 lb
- Weight Note 110Ib/1000ft
- Wire Gauge 12 AWG
- Wire Thickness 0.3438 in
- Wire Width 0.25 in
OMEGALUXâ„¢ CWM (Constant Wattage Medium Temperature) heating cable is the ideal answer to those pipe tracing situations which require higher temperatures for process maintenance as well as freeze protection. No matter what length of cable is needed, wattage (or heat) produced by each foot of cable remains unchanged.
Caution and Warning!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.

Standard Construction
A. Buss wires. Twin 12 AWG copper buss wires provide reliable, consistent electrical current.
B. Buss wire insulation. 11 mil FEP jacket protects and electrically insulates buss wires.
C. Inner sheath. This insulation jacket holds the two buss wires together and provides the wrapping surface for the nichrome heating wire.
D. Nichrome wire. The nichrome resistance heating wire is the heating component of the cable.
E. Jacket. Flame-retardant insulation jacket is made from FEP material which protects heating cable and assures long service life. This material is also highly corrosion resistant.
F. Metal braid. Plated copper braid covering the jacket provides a positive ground path.
G. Optional fluoropolymer overjacket. FEP jacket provides protection from most aqueous and chemically corrosive solutions. Add suffix “-CT†to model number.
Minimum length of heating cable is 25 ft. See Pages B-24 to B-28 for heat cable accessories and controls.
Caution and Warning!
Fire and electrical shock may result if products are used improperly or installed or used by non-qualified personnel. See inside back cover for additional warnings.

Standard Construction
A. Buss wires. Twin 12 AWG copper buss wires provide reliable, consistent electrical current.
B. Buss wire insulation. 11 mil FEP jacket protects and electrically insulates buss wires.
C. Inner sheath. This insulation jacket holds the two buss wires together and provides the wrapping surface for the nichrome heating wire.
D. Nichrome wire. The nichrome resistance heating wire is the heating component of the cable.
E. Jacket. Flame-retardant insulation jacket is made from FEP material which protects heating cable and assures long service life. This material is also highly corrosion resistant.
F. Metal braid. Plated copper braid covering the jacket provides a positive ground path.
G. Optional fluoropolymer overjacket. FEP jacket provides protection from most aqueous and chemically corrosive solutions. Add suffix “-CT†to model number.
Output | Tinned Copper Braid (-C) | FEP Overcoat (-CT) and Tinned Copper Overbraid | Module Length in (mm) | Max Circuit Length feet (m) | |||
Watts/ Foot | Volts | Model No. | Weight lb.(kg)/ 1000' | Model Number | Weight lb.(kg)/ 1000' | ||
4 4 | 120 240 | CWM4-1C CWM4-2C | 96 (43.5) 96 (43.5) | CWM4-1CT CWM4-2CT | 110 (49.9) 110 (49.9) | 18 (457) 30 (762) | 350 (106.6) 700 (213.3) |
8 8 8 | 120 240 480 | CWM8-1C CWM8-2C CWM8-4C | 96 (43.5) 96 (43.5) 96 (43.5) | CWM8-1CT CWM8-2CT CWM8-4CT | 110 (49.9) 110 (49.9) 110 (49.9) | 18 (457) 24 (610) 37 (940) | 245 (74.6) 475 (144.7) 950 (289.5) |
12 12 12 | 120 240 480 | CWM12-1C CWM12-2C CWM12-4C | 96 (43.5) 96 (43.5) 96 (43.5) | CWM12-1CT CWM12-2CT CWM12-4CT | 110 (49.9) 110 (49.9) 110 (49.9) | 12 (305) 24 (610) 30 (762) | 200 (60.9) 400 (121.9) 800 (243.8) |
PDFs & Manuals