Product Specs
<< See all Product ModelsBrand |
![]() |
Additional Features 1 | Trend visualization |
Control Output | 2 SPDT Relay |
Cutout Dimensions | 48 x 96 mm |
Data Interface | RS485 |
Data Interface Note | RS485 Modbus RTU - Slave (1200 ~ 115200 Baud) galvanically isolated from Power supply/Inputs/Outputs |
Display Type | Graphical OLED |
Electrical Connection | Screw Terminal |
Enclosure Material | Polycarbonate V0 |
Enclosure Ratings | IP65, NEMA Type 4 |
Form factor | 1/8 DIN |
Input Type | Themocouple, RTD, Current, Voltage |
Input Type Note | 1 Analogue: Res.16 bit, Selecting for T/C type K, S, R, J, T, E, N, B (automatic compensation of the cold junction 0 ~ 50 °C, ± 0,2% F.S. ± 1 Digit F.S.), thermoresistances PT100, PT500, PT1000, Ni100, PTC1K, NTC10K (ß 3435K), process signals 0-10 V(54000 points), 0/4-20mA(40000 points), 0-60 mV (16000 points), Potentiometer 6 KO, 150 KO (50000 points) Customizable linear input (max 16 steps) 2 Digital: PNP inputs programmable for Run / Hold / Tare-Zero / Alarms reset/ Peaks reset/ Totalizer reset / Activate-Reset Sum / Parameters-Setpoint Lock |
Number of Inputs | 1 |
Operating Temperature, Max | 45 °C |
Operating Temperature, Min | 0 °C |
Output Configurations | 2 Analog Current |
Output Configurations Note | 1 output 0 ~ 10V (60000 points) - 1 output 0/4 ~ 20mA (60000 points) Analogue Retransmission: Process values / Setpoints |
Output Detail | 2A - 250VAC (resistive charge) |
Power Consumption | 8 VA |
Quick Set-up Options | Software LABSOFTVIEW and/or Memorycard |
Relative Humidity | 35 ~ 95 RH% (non condensing) |
Sampling Rate | 4.12 Hz to 242 Hz (4.12 to 242 updates/second) |
Sensor/Transmitter Power | 24 VDC - 30mA for external sensors supply (loop-powered) |
Supply Power Note | 24 ~ 230VAC/DC ±10% 50/60 Hz (galvanic isolation 2500V) |
Supply Power Type | AC/DC |
Supply Voltage | 24 to 230 Vac/Vdc |
Thermocouple Type | J, K, T, E, R, S, B, N |
Weight | 165 g |
See All Specs |
PDFs & Manuals
Software & Drivers
Show Ratings & Reviews