Rated 2 out of 5 by from Accurate but flawed design Initial testing revealed accurate totalized flow but having to pull off the cover (4 screws) every time you want to reset the totalizer is ridiculous. Considering using the 2 unused wires and a couple of PLC outputs to mimic button pressing. So much for the warranty. Can't output the totalized flow number instead of the flowrate.
Date published: 2016-10-26
Rated 5 out of 5 by from Great product and service! Good product and packaging, updates we're provided with tracking
Date published: 2024-06-10
Rated 5 out of 5 by from Good Service Good product and packaging, updates we're provided with tracking
Date published: 2024-06-10
  • y_2025, m_4, d_17, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_FLR6102D, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 29ms
  • REVIEWS, PRODUCT

Can this unit be use with 100% Oxygen

Asked by: Engineer SS
Thank you for your inquiry! These units are not oxygen cleaned and therefore can result in hazardous conditions if used with oxygen. Use with 100% oxygen would not be recommended
Answered by: Application Engineer JM
Date published: 2022-03-10

Can these units be NIST traceably calibrated?

Asked by: BigD
Thank you for your inquiry and it has an option to purchase with a NIST cert. You will need to add as a suffix, '-NIST' to the part number.
Answered by: Application Engineer JC
Date published: 2023-03-06

When looking at the spec sheet for model FLR6750D, it list the medium used "Air 100 psi", is 100 psi the minimum usable pressure? I only see a maximum values listed, 1000psi but no mention of a "minimum psi"

Asked by: Har71
Thank you for your inquiry. The FLR6750D for air measurement is calibrated at 100 PSI and is the required minimum pressure.
Answered by: Applications Engineer JJC
Date published: 2024-07-12

What is the response time for these flow meters? 1 second, 50 milliseconds?

Asked by: Hudson
Thank you for your inquiry! The response time for these units is 1 second
Answered by: Application Engineer JM
Date published: 2021-07-29

Can this unit be used to measure c02 flow and total consumption? Will it data log on the sensor?

Asked by: Artus
Thank you for your inquiry. Unfortunately, no and it does not have a data logger feature. Advise to use the FMA1700/1800A mass flow meter and has an output that can be sent or connected to a separate data logger to record or track the total consumption of gas.
Answered by: Applications Engineer JJC
Date published: 2025-01-25
  • y_2025, m_4, d_18, h_6CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_5
  • loc_en_US, sid_FLR6102D, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 86ms
  • QUESTIONS, PRODUCT
en-US
en_CA
Save Configuration