ip211-ep211
General Purpose Current I/P or Voltage E/P to Pressure Converter
Models In Stock
- Low Cost
- Built-in Volume Booster
- Small Size
- Field Reversible
ip211-ep211
From
C$
613.71
Models In Stock

Product Overview
- Accuracy ± 2.5 %
- Accuracy Note Includes linearity, hysteresis and repeatability
- Electrical Connection DIN 43560 connector
- EMC Standard IEC 61000-4-3
- Enclosure Ratings IP65, NEMA Type 4X
- Enclosure Type N/A
- Flow Rate Note 12 scfm @ 100 psig 20 scfm @ 150 psig
- Input Control Signal N/A
- Materials Stainless Steel, Brass, Zinc, Epoxy, Chromated Aluminum, NBR
- Media Compatibility Clean Dry Air
- Mounting Direct wall, panel, DIN rail
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -30 °C
- Process Connection Size 1/4 in
- Process Connection Type NPT Female
- Supply Pressure Sensitivity 0.1% of span per psi (±0.02% for zero-based units)
- Total Air Consumption 6 SCFH
- Volumetric Flow Rate, Max 12 SCFM
- Weight 590 g
Description
The IP211/EP211 Series transducer is an electropneumatic device that reduces a supply pressure to a regulated output pressure directly proportional to an electrical input signal. The 211 Series accepts a wide range of supply pressures, ranging from a minimum of 3 psig (0.2 BAR) above the maximum output up to 100 psig (6.9 BAR). An integral pneumatic volume booster is included in the design to provide high flow capacity (up to 12 SCFM). Model selection includes General Purpose, FM Intrinsically Safe, and CSA Intrinsically Safe.Mounting
These transducers can be pipe, panel, or bracket mounted in any position. Positions other than verticle will require recalibration of the zero adjustment. For maximum output stability the transducers should be mounted in a vibration free location or such that vibration is isolated in the X and Z axis.
Field Reversible
All transducers are calibrated at the factory for direct acting operation but may be used in the reverse acting mode by reversing the polarity of the signal leads and recalibrating. When recalibrated for reverse acting applications, the transducers provide a minimum of their full rated output pressure (i.e.15, 27, or 30 psig) upon input signal failure.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
RAFAEL70 from
GREAT FEATURES
ALL RIGHT THIS IS A EXCELLENT PRODUCT I USED THIS IN SEVERAL OCCASIONS
Date published: 2015-11-24
Rated 5 out of
5
by
Anonymous from
Kept me going!
I received may order very quickly. It was packed carefully and arrived undamaged. I will use Omega again!!!
Date published: 2023-03-13
Rated 1 out of
5
by
no name from
second hand product
we received a second hand product, not new! scratched and many spots dispainted
Date published: 2020-06-28