Welcome to our new website, found an issue or bug? Please report it here

PX1004
High Temperature Pressure Transducers with AS5202 Port
- High Operating Temperature
- PX1004: 232°C (450°F)
- PX1009: 343°C (650°F)
- High Performance ± 0.25% BSL Full Scale
PX1004
From
C$
2,747.48

Product Overview
- Accuracy ± 0.25 %
- Accuracy Class 0.1% to 0.25%
- Accuracy Note Combined linearity, hysteresis and repeatability: ± 0.25% FSO, BSL (over the compensated temperature range)
- Additional Features 1 None
- Compensated Temperature, Min 24 °C
- Electrical Output 3 mV/V
- Input Resistance 400 Ω
- Materials, Wetted 17-4 Stainless Steel
- Mounting Case isolation ensures that the sensing element will not be affected by external stresses
- Natural frequency 50 kHz at 5000 psi decreasing logarithmically to 5 kHz at 15 psi
- Operating Temperature, Min -54 °C
- Output Resistance 400 Ω
- Output Signal Millivolt
- Pressure, Min 0 bar
- Process Connection Size 1/4 in
- Process Connection Type AS5205/MS33656-4 Male
- Relative Humidity Per MIL-STD-810, Method 507.1
- Residual Unbalance 0 mV ± 5% FSO at zero pressure
- Sensing Element 4-active-arm Strain Gauge Bridge
- Sensing Element Note 4-active-arm bridge using sputter-deposited thin-film elements
- Shock 100 g, 11 ms, half sine wave without calibration shift or damage
- Supply Voltage 10 Vdc
- Thermal Effect on Span error, Max ± 0.01% FSO/°F
- Thermal Effect on Zero error, Max ± 0.01% FSO/°F, ± 0.01% FSO/°F
- Voltage Output, Min 26 mV
- Weight 145 g
Description
OMEGA’s PX1004 and PX1009 Sputtered Thin Film Pressure Transducers are designed for high temperature applications. These transducers can operate in temperature ranges from -65°F to +450°F or +650°F. Yet, even in these difficult high temperatures, they provide outstanding accuracy, long-term calibration stability and reliability. Static accuracy is ± 0.25%, and thermal zero and sensitivity shifts over their compensated range are less than ± 0.01%/°F. OMEGA’s thin film technology makes this premium performance possible. The strain gages are sputter-deposited, forming a molecular bond with the substrate. There is virtually no shift, drift, or creep to cause the transducer’s calibration to change. The all-welded stainless steel pressure cavity and double-isolated case ensures pressure integrity and reliability in these tough environments. These high-temperature transducers are available in many standard ranges from 15 psi to 10,000 psi (specify gage or absolute pressure). A NIST traceable calibration record is available for these units.For special options consult Sales or Pressure Engineering.
Examples of pricing for popular models is referenced in the "To Order" box. Use the "Part Number Builder" below to get pricing for all available models.
Note: Ultra-High Temperature PX1009 Transducers are built to order. Check with sales for availability.
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
RodneyB332 from
Great product
Great quality! This product works as intended. We have no issues.
Date published: 2023-10-03
Can these be used to measure liquid/oils?
These are not recommended to use with oil as could be explosion risk.
Date published: 2024-07-03
What adaptor part (pressure side) will work for this pressure transducer? Can you refer to a product?
Juli, what do you want this adapted to? NPT? What pressure range are you looking at and what is the full part number?
Kindly email pressure@dwyeromega.com, we ca send you the list of adaptors we offer.
Date published: 2024-11-01